Fan speed (3).
Supply air temperature (21 

°

C).

Post-heating is on.
Time.
Filter guard alert.

Maintenance reminder alert.
Fireplace / booster switch on. The fireplace /
booster switch is activated in this display by
simultaneously pressing down the + and – buttons
for 2 seconds.
Week clock control on.

21 C

10:20

VALLOX 280 SE

INSTRUCTIONS FOR USING THE CONTROL PANEL

8

© VALLOX • We reserve the right to make changes without prior notification.

1

2

3

4

5

6

7

8

2.2. 

Operating menu

In order to move the control panel to the settings menu, press the + and – buttons simultaneously.
In the settings menu, you can change setpoints for the ventilation unit.

The content display shows humidity and carbon dioxide content. The corresponding
sensors are required (options).

The temperature display shows the temperatures of outdoor air, indoor air, supply air
and exhaust air. The accuracy of the temperature sensors is 

±

 2 

°

C.

Supply air temperature setting is changed with the + and – buttons.

2.2.1.  Main display and change of fan speed

2.2.2.  Moving to the settings menu

2.2.4.  Content display

2.2.5. Temperature 

display

2.2.6.  Setting supply air temperature

Fan speed can be changed in this display with the + and – buttons
(see section 2.1., items 7 and 8 in the figure).

The displays of the operating menu (sections 2.2.1.–2.2.6.) can be scrolled with the scrolling buttons
(see section 2.1., items 5 and 6 in the figure).

To settings menu
See manual

RH1 35%     RH2   40%
CO2           0821  PPM

Out 20 

In 20

Sup. 20 

Exh. 20

Temp. setting
20C

5

Scrolling up

With this button, you can scroll the displays upward.

6

Scrolling down

With this button, you can scroll the displays downward.

7

Increase button

With this button, you can increase values.

8

Decrease button

With this button, you can decrease values.

2

Carbon dioxide adjustment

With this button, you set carbon dioxide
adjustment on and off. When the indicator is
lit, the adjustment is on.

3

Humidity adjustment

With this button, you set humidity adjustment
on and off. When the indicator is lit, the
adjustment is on.

4

Post-heating

With this button, you set post-heating on and
off. When the indicator is lit, post-heating is on.
The summer function is active when the indicator
is not lit.

2.1. Keyboard

Power failure

After a power failure, the unit starts at minimum
fan speed. The adjustments and setpoints chosen
will remain in the memory of the unit in spite of
the power failure.

2.

Control panel

1

Start button

With this button, you switch the unit on and off.
When the indicator is lit, the unit is on.

3

21 C

3

10:20

Week clock control can be activated by pressing the + button and deactivated by pressing the –
button. Week clock control is on when the symbol of week clock control is shown in the main
display. In week clock control, the basic fan speed and supply air temperature of the unit are
adjusted in accordance with the programme in section 2.3.4.

2.2.3.  Week clock control

Week program
on

Summary of Contents for 280 SE

Page 1: ...ake changes without prior notification 1 09 372E 19 8 2008 Code 3487 VALLOX INSTRUCTIONS FOR USE AND MAINTENANCE DIGIT SED ELECTRONIC CONTROLLER WITH LCD DISPLAY Electronically controlled supply extra...

Page 2: ...ascade control p 5 1 12 Heat recovery bypass function p 5 1 13 Anti frost function of heat recovery cell p 6 1 14 Anti frost function in a water circulated post heating unit p 6 1 15 Maintenance remin...

Page 3: ...nit 6 C 15 C exhaust air Changing the setpoints There may be three control panels at most When more than one control panel is used the unit can be adjusted at all the control panels VALLOX We reserve...

Page 4: ...od indoor air is approximately 45 When this control is on the control panel may be used to raise fan speed to the set maximum fan speed and to decrease it to the basic fan speed In humidity control fa...

Page 5: ...The temperature of air blown to the ventilation zone is controlled on the basis of extract air The program tries to keep supply air temperature at a value determined by the difference between extract...

Page 6: ...reezing The automatic function stops the supply and extract air fans as soon as outdoor air temperature falls below 0 C and supply air temperature below 7 C in which case also the control valve become...

Page 7: ...es for 45 minutes During the function the fireplace booster switch symbol is visible in the main display of the control panel The function is selected at the control panel see Section 2 2 1 NOTE The s...

Page 8: ...1 items 5 and 6 in the figure To settings menu See manual RH1 35 RH2 40 CO2 0821 PPM Out 20 In 20 Sup 20 Exh 20 Temp setting 20C 5 Scrolling up With this button you can scroll the displays upward 6 S...

Page 9: ...actory settings see manual The adjustment interval for humidity and carbon dioxide adjustments is selected with the and buttons The adjustment interval refers to minutes 2 3 9 Adjustment interval Adju...

Page 10: ...40 The desired cell bypass temperature is selected with the and buttons If outdoor temperature is lower than cell bypass temperature the summer winter damper is in the winter position 2 3 15 Changing...

Page 11: ...d Exit and pressing or Changes in fan speed Sp and supply air temperature Tmp are only made for the hours desired in other cases use N no change to previous Monday D 1 07 00 hours H 7 fan speed 2 Sp 2...

Page 12: ...ezing protection cell 3 C Freezing protection hysteresis 3 C Preheating setting 5 C Maintenance reminder 4 months Cell bypass 12 C Cascade control not used Humidity level RH level adjustment automatic...

Page 13: ...filter can be cleaned with 25 C 30 C water and washing up liquid It must not be washed or dried roughly but by pressing gently When washing is done properly filters stand cleaning 4 to 5 times F5 and...

Page 14: ...ater connections remove the socle If a condensing water tank is in use it can be drawn out by pulling it forward The tank can be removed for emptying and cleaning When the condensing water outlet is i...

Page 15: ...using the control panel Section 2 3 22 If the preheating radiator does not operate check if over heating protection prevents it from operating press the overheating protection reset button and measure...

Page 16: ...the control card behind a protecting plate the electronics inside the unit may have blown 12 Check the door switch and fuses The unit includes a T800 mA glass tube fuse If needed contact a maintenanc...