VALLOX 70 COMPACT
© VALLOX • We reserve the right to make changes without prior notification.
What the units include can vary depending on the sales area.
VENTILATION ADJUSTMENT
4
HEAT RECOVERY BYPASS
FIREPLACE SWITCH FUNCTION (option)
Speed selector
Cooker hood PTXP/I 130
Speed selector
The VALLOX 70 COMPACT delivery includes a four-step switch. The flush-mounted switch
can be mounted in a standard instrument box. The switch can be used to select four of
the seven speeds for the unit. The speeds selected for the unit are 1, 2, 3 and 4. An
expert can select different speeds at the transformer of the unit.
Control with a cooker hood
When desired, cooking smoke abatement can be connected directly to VALLOX 70
COMPACT and controlled with cooker hood VALLOX PTXP / I 130.
Winter use
In winter use the heat recovery cell of VALLOX COMPACT recovers heat
from the air leaving the dwelling and uses it to heat the air coming from the
outside.
Summer use
The heat recovery cell is bypassed in VALLOX 70 COMPACT with an in-built damper.
In the summer position air flow through the cell is prevented, and heat recovery
bypass is activated.
If the unit has been equipped with a fireplace switch (timer), it can be used to stop
the extract air fan for a certain period, such as 15 minutes, producing overpressure
in the ventilation zone. This makes it easier to light the fireplace, for instance.
The situation will normalise in a while, after the functions stops.
Note! The starting of the extract air fan may weaken draught in the fireplace.