MAINTENANCE INSTRUCTIONS

CONDENSING WATER

During the heating season, humidity of extract air condenses to water. Water formation may
be abundant in new buildings or if ventilation is low compared to the humidity build-up
caused by the residents.

Condensing water needs to flow out from the ventilation unit without hindrance. In connection
with maintenance, e.g. in autumn before the beginning of the heating season, make sure
that the condensing water outlet in the bottom reservoir is not clogged. You may check it by
pouring a little water in the tank.

Do not let water flow to electrical devices.

Other cleaning

In connection with maintenance, also check the inner surface of the unit as well as the
condensing water tank. If they are dirty, clean them gently with a damp cloth, brush, vacuum
cleaner or similar. Keep the unit clean to ensure its flawless operation and hygiene.

COOKER HOOD GREASE FILTER

The grease filter of the cooker hood has to be cleaned 1 to
2 times a month, depending on the use of the hood. The
grease filter can be washed with hot water and washing-
up liquid or in a dishwasher.

Remove the grease filter by pressing the quick couplings (1)
open, letting the bottom plate go in the down position and
removing the filter from its clips (2).

LAMP

To change the lamp, remove the cover glass of the lamp by
pushing it to the left and put a new lamp and cover glass
in place. Lamp type is PL 11 (11 W).

OTHER PARTS OF THE VENTILATION SYSTEM

Ductwork

In blocks of flats and terraced houses, the housing company takes
care of the maintenance and cleaning of the ductwork in accordance
with the regulations and instructions. In detached houses, the owner
takes care of the cleaning.

Valves

The valves may be gently cleaned on the surface. It is forbidden to
remove the valves and to change their adjustment values. Room dust
may also gather around the supply air filter. The easiest way to
remove it is to vacuum the valve with a brush nozzle. Dirt does not
come from the ductwork with ventilation, but consists of dust in indoor
air. This dust sticks to the ceiling or the wall caused by the flow
coming from the valve.

1

2

VALVE OPERATION

Clean air

Dusty indoor air sticks
to the ceiling drawn
by clean air

Summary of Contents for 70 COMPACT R

Page 1: ...depending on the sales area 1 09 349E 11 10 2012 VALLOX CODE 70 Compact A3475 70K Compact A3476 Supply and extract air ventilation with heat recovery For blocks of flats terraced houses and detached...

Page 2: ...11 13 12 15 14 Main parts VALLOX 70 COMPACT EVERYDAY QUICK GUIDE VALLOX 70 COMPACT has been initially adjusted for normal circumstances in your home Ventilation adjustment is needed mainly in the foll...

Page 3: ...outer wall structures remain dry Humidity in indoor air is not condensed in the ventilation ducts Air is fresh in the toilet as well How much air is replaced For air to be clean to breathe it has to b...

Page 4: ...speed 3 or 4 when the filters are clean Fireplace switch function option If the unit has been equipped with a fireplace switch timer it can be used to stop the extract air fan for a certain period suc...

Page 5: ...elling is negatively pressured compared to outdoor air If the dwelling is positively pressured air in the dwelling penetrates the outer envelope of the building and between windows which may cause hum...

Page 6: ...separate extract air valve in the kitchen connected to the ventilation unit The unit is controlled with a separate control centre Speed selection switch The regulator switch is only used to control th...

Page 7: ...00 W electric radiator used for heating supply air The temperature of supply air is adjusted at the thermostat regulator located inside the unit Temperature adjustment range is 0 25 C It is advisable...

Page 8: ...o heat the air coming from the outside The damper is in the down position In summer use when it is warm outside it is unnecessary to heat outdoor air The heat recovery cells are then bypassed with the...

Page 9: ...to replace filters in autumn This way the filters stay cleaner through the winter and can effectively filter off dust in the following spring In connection with the cleaning of the filters it is also...

Page 10: ...ixed to the fan over the rubber collar F flange by turning the ear to the upright position Lift the rubber collar out of the opening and turn the fan so that it can be lifted away from the support M R...

Page 11: ...cooker hood has to be cleaned 1 to 2 times a month depending on the use of the hood The grease filter can be washed with hot water and washing up liquid or in a dishwasher Remove the grease filter by...

Page 12: ...HIS Measure the temperature of supply air in the unit and compare it with the air coming from the valve see page 7 Check the insulation of the attic ducts Check the operation of the defrost thermostat...

Reviews: