VALLOX 70 COMPACT

MAIN PARTS

2

2

Extract air fan

Supply air fan

Preheating radiator

Post-heating radiator

Heat recovery cells (2)

1

2

3

5

6

4

7

8

9

10

10

Outdoor air filter F7

Outdoor air filter G4

Extract air filter G4

Summer / winter damper

Summer / winter damper lock

The picture shows VALLOX 70 COMPACT model R

14

15

16

17

Light switch

Speed selector switch

Damper controller

Post-heating/filter guard indicator
(filter guard is an option)

14

15

16

17

VALLOX 70K COMPACT model R

Hood parts VALLOX 70K COMPACT

11

12

13

Measuring outlets (behind the plate)

Thermostat regulator
of the post-heating radiator

Freezing protection adjustment

Filter guard (option)

filter guard indicator lamp (option)

14

15

1

2

3

4

5

8

6

7

9

10

11

13

12

15

14

Main parts VALLOX 70 COMPACT

EVERYDAY QUICK GUIDE

VALLOX 70 COMPACT has been initially adjusted
for normal circumstances in your home.
Ventilation adjustment is needed mainly in the
following circumstances:

• Cooking:

When the ventilation unit is connected to a
cooker hood, boost ventilation during
cooking (the most common way of abating
cooking smokes in blocks of flats). Small
detached houses and terraced houses are
normally equipped with a separate cooker
hood.

• Empty dwelling:

To save energy, ventilation can be adjusted
to the minimum level.

• Sleeping:

Ventilation in a bedroom has to be
sufficient throughout the night. The level is
correct when air does not smell fusty when
you enter the room in the morning.

• Washing and drying clothes:

Boost ventilation in washing and drying
facilities during these activities.

• Taking a bath:

Boost ventilation in bathing and washing
facilities in order to ensure that the rooms
get dry as quickly as possible. It is
recommended to have boosted ventilation
on for 2 to 3 hours after taking a sauna
bath.

Summary of Contents for 70 COMPACT R

Page 1: ...depending on the sales area 1 09 349E 11 10 2012 VALLOX CODE 70 Compact A3475 70K Compact A3476 Supply and extract air ventilation with heat recovery For blocks of flats terraced houses and detached...

Page 2: ...11 13 12 15 14 Main parts VALLOX 70 COMPACT EVERYDAY QUICK GUIDE VALLOX 70 COMPACT has been initially adjusted for normal circumstances in your home Ventilation adjustment is needed mainly in the foll...

Page 3: ...outer wall structures remain dry Humidity in indoor air is not condensed in the ventilation ducts Air is fresh in the toilet as well How much air is replaced For air to be clean to breathe it has to b...

Page 4: ...speed 3 or 4 when the filters are clean Fireplace switch function option If the unit has been equipped with a fireplace switch timer it can be used to stop the extract air fan for a certain period suc...

Page 5: ...elling is negatively pressured compared to outdoor air If the dwelling is positively pressured air in the dwelling penetrates the outer envelope of the building and between windows which may cause hum...

Page 6: ...separate extract air valve in the kitchen connected to the ventilation unit The unit is controlled with a separate control centre Speed selection switch The regulator switch is only used to control th...

Page 7: ...00 W electric radiator used for heating supply air The temperature of supply air is adjusted at the thermostat regulator located inside the unit Temperature adjustment range is 0 25 C It is advisable...

Page 8: ...o heat the air coming from the outside The damper is in the down position In summer use when it is warm outside it is unnecessary to heat outdoor air The heat recovery cells are then bypassed with the...

Page 9: ...to replace filters in autumn This way the filters stay cleaner through the winter and can effectively filter off dust in the following spring In connection with the cleaning of the filters it is also...

Page 10: ...ixed to the fan over the rubber collar F flange by turning the ear to the upright position Lift the rubber collar out of the opening and turn the fan so that it can be lifted away from the support M R...

Page 11: ...cooker hood has to be cleaned 1 to 2 times a month depending on the use of the hood The grease filter can be washed with hot water and washing up liquid or in a dishwasher Remove the grease filter by...

Page 12: ...HIS Measure the temperature of supply air in the unit and compare it with the air coming from the valve see page 7 Check the insulation of the attic ducts Check the operation of the defrost thermostat...