1.   THREE QUESTIONS ABOUT VENTILATION

Why is air replaced in dwellings?

Good ventilation promotes healthy living for both residents and the building

. Air in a dwelling needs to

be replaced in order to remove not only humidity brought about by living but also impurities
emanating from structures and human bodies. Impurities of indoor air include carbon dioxide,
formaldehyde, radon and other gases as well as dust.

Mechanical ventilation is needed in order to be able to adjust air circulation as needed by
the residents. In a tightly sealed house, air does not circulate sufficiently by natural means.
Even in a poorly sealed house air is only replaced because of differences between indoor
and outdoor air temperatures, or because of winds. This means that ventilation is dependent
on weather conditions and cannot be regulated.

It is especially important that humidity and carbon dioxide content of the indoor air stay at
a healthy level. Recommended humidity content of good indoor air is approximately 45%.
Humidity content is lower in winter and higher in summer and autumn. Dust mites thrive in
indoor air if humidity exceeds 50%, and if humidity stays at over 60% for a long time in
winter, water will condense in the cold structures of the house and mould will start to form.

The recommended maximum carbon dioxide content in good indoor air is circa 1,000 ppm.

What are the characteristics of adequate ventilation?

• Indoor air stays fresh in all the rooms of the dwelling, also in bedrooms during night.

Without adequate ventilation carbon dioxide content tends to rise high especially in bedrooms.

• The bathroom and the sauna get dry quickly.
• During the heating season, the windows and other outer wall structures remain dry.
• Humidity in indoor air is not condensed in the ventilation ducts.
• Air is fresh in the toilet as well.

How much air is replaced?

For air to be clean to breathe, it 

has to be replaced with outdoor air every two hours

. In a new and

a renovated house, air needs to be circulated continually, at least once an hour, during the
first year in order to remove harmful gases and structural humidity. In buildings that are more
than a year old and dry, ventilation can be regulated as needed. Ventilation is boosted
during for instance a sauna bath, clothes washing and cooking, and reduced during very
cold periods or when there is nobody at home.

Window ventilation

Dwelling-specific supply / extract air circulation by no means prevents you from opening
windows and the door to the balcony or airing through them. In window or door ventilation
attention needs to be paid to the following factors:

1.  During the heating season window ventilation uncontrollably consumes a considerable

amount of energy.

2.  An open window lets in dusty and dirty air.
3.  An open window also lets in noise pollution.

SEASONAL CALENDAR

Spring:

•  Wash or change the coarse filter and clean or

change the fine filter if needed.

•  Clean the fan blades and the post-heating

unit if needed.

•  Check that summer ventilation is in

operation. Extract air does then not heat air
coming from the outside.

NOTE!
For further details, see inner pages.

Autumn

•  Wash or change the coarse filter and clean

or change the fine filter if needed.

•  Check that the heat recovery cell is clean.

•  Check that the condensing water outlet is

not clogged.

•  Switch summer ventilation off.

This appliance can be used by children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and knowledge
if they have been given supervision or instruction concerning use of the appliance in a
safe way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.

Summary of Contents for 70 COMPACT R

Page 1: ...depending on the sales area 1 09 349E 11 10 2012 VALLOX CODE 70 Compact A3475 70K Compact A3476 Supply and extract air ventilation with heat recovery For blocks of flats terraced houses and detached...

Page 2: ...11 13 12 15 14 Main parts VALLOX 70 COMPACT EVERYDAY QUICK GUIDE VALLOX 70 COMPACT has been initially adjusted for normal circumstances in your home Ventilation adjustment is needed mainly in the foll...

Page 3: ...outer wall structures remain dry Humidity in indoor air is not condensed in the ventilation ducts Air is fresh in the toilet as well How much air is replaced For air to be clean to breathe it has to b...

Page 4: ...speed 3 or 4 when the filters are clean Fireplace switch function option If the unit has been equipped with a fireplace switch timer it can be used to stop the extract air fan for a certain period suc...

Page 5: ...elling is negatively pressured compared to outdoor air If the dwelling is positively pressured air in the dwelling penetrates the outer envelope of the building and between windows which may cause hum...

Page 6: ...separate extract air valve in the kitchen connected to the ventilation unit The unit is controlled with a separate control centre Speed selection switch The regulator switch is only used to control th...

Page 7: ...00 W electric radiator used for heating supply air The temperature of supply air is adjusted at the thermostat regulator located inside the unit Temperature adjustment range is 0 25 C It is advisable...

Page 8: ...o heat the air coming from the outside The damper is in the down position In summer use when it is warm outside it is unnecessary to heat outdoor air The heat recovery cells are then bypassed with the...

Page 9: ...to replace filters in autumn This way the filters stay cleaner through the winter and can effectively filter off dust in the following spring In connection with the cleaning of the filters it is also...

Page 10: ...ixed to the fan over the rubber collar F flange by turning the ear to the upright position Lift the rubber collar out of the opening and turn the fan so that it can be lifted away from the support M R...

Page 11: ...cooker hood has to be cleaned 1 to 2 times a month depending on the use of the hood The grease filter can be washed with hot water and washing up liquid or in a dishwasher Remove the grease filter by...

Page 12: ...HIS Measure the temperature of supply air in the unit and compare it with the air coming from the valve see page 7 Check the insulation of the attic ducts Check the operation of the defrost thermostat...

Reviews: