VALLOX 70 COMPACT

8

INSTRUCTIONS FOR USE

In winter use

 the heat recovery cells of VALLOX 70 COMPACT recover heat from the air

leaving the dwelling and use it to heat the air coming from the outside. The damper is in
the down position.

In summer use

 when it is warm outside, it is unnecessary to heat outdoor air. The heat recovery

cells are then bypassed with the standard damper (A). The damper is lifted up and locked
with a clamp (B). In the summer position air flow through the cell is prevented, and heat
recovery bypass is activated. In summer set the post-heating thermostat at 0 

°

C position so

that the radiator will not heat.

SUMMER / WINTER VENTILATION

A

B

Summary of Contents for 70 COMPACT R

Page 1: ...depending on the sales area 1 09 349E 11 10 2012 VALLOX CODE 70 Compact A3475 70K Compact A3476 Supply and extract air ventilation with heat recovery For blocks of flats terraced houses and detached...

Page 2: ...11 13 12 15 14 Main parts VALLOX 70 COMPACT EVERYDAY QUICK GUIDE VALLOX 70 COMPACT has been initially adjusted for normal circumstances in your home Ventilation adjustment is needed mainly in the foll...

Page 3: ...outer wall structures remain dry Humidity in indoor air is not condensed in the ventilation ducts Air is fresh in the toilet as well How much air is replaced For air to be clean to breathe it has to b...

Page 4: ...speed 3 or 4 when the filters are clean Fireplace switch function option If the unit has been equipped with a fireplace switch timer it can be used to stop the extract air fan for a certain period suc...

Page 5: ...elling is negatively pressured compared to outdoor air If the dwelling is positively pressured air in the dwelling penetrates the outer envelope of the building and between windows which may cause hum...

Page 6: ...separate extract air valve in the kitchen connected to the ventilation unit The unit is controlled with a separate control centre Speed selection switch The regulator switch is only used to control th...

Page 7: ...00 W electric radiator used for heating supply air The temperature of supply air is adjusted at the thermostat regulator located inside the unit Temperature adjustment range is 0 25 C It is advisable...

Page 8: ...o heat the air coming from the outside The damper is in the down position In summer use when it is warm outside it is unnecessary to heat outdoor air The heat recovery cells are then bypassed with the...

Page 9: ...to replace filters in autumn This way the filters stay cleaner through the winter and can effectively filter off dust in the following spring In connection with the cleaning of the filters it is also...

Page 10: ...ixed to the fan over the rubber collar F flange by turning the ear to the upright position Lift the rubber collar out of the opening and turn the fan so that it can be lifted away from the support M R...

Page 11: ...cooker hood has to be cleaned 1 to 2 times a month depending on the use of the hood The grease filter can be washed with hot water and washing up liquid or in a dishwasher Remove the grease filter by...

Page 12: ...HIS Measure the temperature of supply air in the unit and compare it with the air coming from the valve see page 7 Check the insulation of the attic ducts Check the operation of the defrost thermostat...