MAINTENANCE INSTRUCTIONS

MAINTENANCE

In blocks of flats and terraced houses, the maintenance of the unit is taken care
of by a property maintenance company or the user, depending on the contract.

Before starting maintenance activities, stop the machine either at the ON/OFF
switch or by removing the fuse from the fuse panel of the dwelling. The safety
switch also turns the unit off when the door is opened.

FILTERS

Outdoor air is filtered in the unit with two types of filters. A G4 class
coarse filter (A) filters off insects, rough pollen and other dust. An F7
class fine filter (B) filters off invisible dust. Extract air is filtered with a
similar G4 class filter as outside air.

Clean the coarse filters (A) by washing them at least two to four times
a year (and more often if needed). Wash a coarse filter with
+25…30 

°

C warm water and washing-up liquid, pressing it smoothly.

Do not handle the filters with force. Filters stand cleaning when it is
done properly. They have to be replaced at least every year or when
needed.

The fine filter (B) is not washable. Clean it at the same time as the
coarse filters, using the brush nozzle of a vacuum cleaner. When
cleaning, be careful no to break filter material. To ensure good supply
air quality, replace the filter when needed, preferably at one-year
intervals, depending on local air quality. It is recommended to replace
filters in autumn. This way the filters stay cleaner through the winter
and can effectively filter off dust in the following spring.

In connection with the cleaning of the filters, it is also advisable to check
the cleanliness of the heat recovery cells (C) every two years or so.
Grab the ears at the ends of the cell and pull the cell out of the unit. If
the cell is contaminated, soak it in a solution of water and washing-up
liquid.

Rinse the cell clean with a jet of water. When all the water has drained
from between the laminas, push the cell back so that the sealings next
to the sliding surfaces are in place and the "up" sticker at the end of
the cell points to the corner next to the upper support.

In addition, check in autumn and spring the position of the summer /
winter damper and the leaving of condensing water from the unit as
well as the position of the post-heating radiator thermostat.

Filter guard

VALLOX 70 COMPACT can be equipped with an 

optional

 filter guard.

The filter guard indicator lights up at speeds 3 and 4 when the filters
are clean; this is normal and does not call for any maintenance activities.
If the indicator does not light up at speed 4, the pressure in the ventilation
ductwork of the building differs from the factory setting. When needed,
an expert may change the setpoint. 

If the filter guard symbol already lights

up at fan speed 1 or 2, the filters need cleaning

. If they are clean, the lighting

up may be caused by a clogged up dense mosquito net installed against
mounting instructions in the external grille or by the closing of the supply
air valves in the rooms.

70 Compact

70K Compact

Indicator lamp

Filter guard

Indicator lamp

Filter guard

A

B

C

Summary of Contents for 70 COMPACT R

Page 1: ...depending on the sales area 1 09 349E 11 10 2012 VALLOX CODE 70 Compact A3475 70K Compact A3476 Supply and extract air ventilation with heat recovery For blocks of flats terraced houses and detached...

Page 2: ...11 13 12 15 14 Main parts VALLOX 70 COMPACT EVERYDAY QUICK GUIDE VALLOX 70 COMPACT has been initially adjusted for normal circumstances in your home Ventilation adjustment is needed mainly in the foll...

Page 3: ...outer wall structures remain dry Humidity in indoor air is not condensed in the ventilation ducts Air is fresh in the toilet as well How much air is replaced For air to be clean to breathe it has to b...

Page 4: ...speed 3 or 4 when the filters are clean Fireplace switch function option If the unit has been equipped with a fireplace switch timer it can be used to stop the extract air fan for a certain period suc...

Page 5: ...elling is negatively pressured compared to outdoor air If the dwelling is positively pressured air in the dwelling penetrates the outer envelope of the building and between windows which may cause hum...

Page 6: ...separate extract air valve in the kitchen connected to the ventilation unit The unit is controlled with a separate control centre Speed selection switch The regulator switch is only used to control th...

Page 7: ...00 W electric radiator used for heating supply air The temperature of supply air is adjusted at the thermostat regulator located inside the unit Temperature adjustment range is 0 25 C It is advisable...

Page 8: ...o heat the air coming from the outside The damper is in the down position In summer use when it is warm outside it is unnecessary to heat outdoor air The heat recovery cells are then bypassed with the...

Page 9: ...to replace filters in autumn This way the filters stay cleaner through the winter and can effectively filter off dust in the following spring In connection with the cleaning of the filters it is also...

Page 10: ...ixed to the fan over the rubber collar F flange by turning the ear to the upright position Lift the rubber collar out of the opening and turn the fan so that it can be lifted away from the support M R...

Page 11: ...cooker hood has to be cleaned 1 to 2 times a month depending on the use of the hood The grease filter can be washed with hot water and washing up liquid or in a dishwasher Remove the grease filter by...

Page 12: ...HIS Measure the temperature of supply air in the unit and compare it with the air coming from the valve see page 7 Check the insulation of the attic ducts Check the operation of the defrost thermostat...

Reviews: