background image

Manual

Model

Vallox Exxeo 150

Vallox Exxeo 150 DS 

Vallox Exxeo 150 DPC 

Vallox Exxeo 300

Vallox Exxeo 300 DS 

Vallox Exxeo 300 DPC 

Vallox Exxeo 700

Vallox Exxeo 700 DS 

Vallox Exxeo 700 DPC 

Vallox Exxeo 1400

Vallox Exxeo 1400 DS 

Vallox Exxeo 1400 DPC 

Document

D11341

 

Valid from

01.12.2023

Updated

10.11.2023

Roof fans

MANU

AL

Vallox Exxeo 2000

Vallox Exxeo 2000 DS 

Vallox Exxeo 2000 DPC 

Vallox Exxeo 2500

Vallox Exxeo 2500 DS 

Vallox Exxeo 2500 DPC 

Vallox Exxeo 4100

Vallox Exxeo 4100 DS 

Vallox Exxeo 4100 DPC

Summary of Contents for Exxeo 150

Page 1: ...Exxeo 700 DS Vallox Exxeo 700 DPC Vallox Exxeo 1400 Vallox Exxeo 1400 DS Vallox Exxeo 1400 DPC Document D11341 Valid from 01 12 2023 Updated 10 11 2023 Roof fans MANUAL Vallox Exxeo 2000 Vallox Exxeo...

Page 2: ...use of the ventilation system or control unit Incorrect or inappropriate installation setup or use Negligence of instructions concerning transport installation use or maintenance Changes made to the...

Page 3: ...tages INTRODUCTION TRANSPORT AND STORAGE Check the roof fan for any transport damage immediately after receiving it If you detect damage caused during transport contact the transporter immediately The...

Page 4: ...ting cable with 7 poles 2x3 phase supply PE model marking e g Vallox Exxeo 4100 DS air volume 4 100 dm s ps 150 Pa NOTE If the roof fan is used as an extract fan for a kitchen grease duct grease remov...

Page 5: ...o 2500 DS 101 3 400 VAC 50 Hz 1 100 1 85 IP55 Similar to an old AC dual speed roof fan Vallox Exxeo 2500 DPC 99 3 400 VAC 50 Hz 1 100 1 85 IP55 2 speed or 0 10 V control pressure and air volume contro...

Page 6: ...V 8 V 8 V 10 V Sound values 40 65 45 50 55 60 0 70 75 0 1 0 05 0 15 0 2 0 25 4 V LwA 6 V LwA 10 V LwA 8 V LwA Static pressure difference p Pa Air volume flow rate m3 s Input power P W Air volume flow...

Page 7: ...0 3 0 4 0 5 10 V 8 V 6 V 4 V 4 V 6 V 8 V 10 V Sound values 40 65 45 50 55 60 0 15 0 70 75 0 05 0 1 0 25 0 2 0 3 0 35 0 4 0 45 4 V LwA 6 V LwA 10 V LwA 8 V LwA Static pressure difference p Pa Air volu...

Page 8: ...8 V 10 V Sound values 45 70 50 55 60 65 0 3 0 75 80 10 V LwA 8 V LwA 6 V LwA 4 V LwA 0 1 0 2 0 5 0 4 0 6 0 7 0 8 0 9 Air volume flow rate m3 s Input power P W Air volume flow rate m3 s Air volume flo...

Page 9: ...V 6 V 4 V 4 V 6 V 8 V 10 V Sound values 45 70 50 55 60 65 0 6 0 75 85 0 2 0 4 1 0 0 8 1 2 1 4 1 6 80 4 V LwA 6 V LwA 8 V LwA 10 V LwA Air volume flow rate m3 s Air volume flow rate m3 s Air volume flo...

Page 10: ...0 50 60 1200 10 V 8 V 6 V 4 V 4 V 6 V 8 V 10 V Sound values 45 70 50 55 60 65 0 75 0 5 1 0 1 5 2 0 80 10 V LwA 8 V LwA 6 V LwA 4 V LwA Air volume flow rate m3 s Input power P W Air volume flow rate m3...

Page 11: ...80 1400 1200 3 0 3 5 60 70 10 V 8 V 6 V 4 V 4 V 6 V 8 V 10 V Sound values 45 70 50 55 60 65 0 5 1 0 0 2 5 1 5 2 0 75 3 0 80 10 V LwA 8 V LwA 6 V LwA 4 V LwA Air volume flow rate m3 s Air volume flow...

Page 12: ...V 8 V 6 V 4 V 4 V 6 V 8 V 10 V Sound values 50 70 90 55 60 65 0 75 0 5 1 0 1 5 2 0 80 2 5 3 0 3 5 4 0 4 5 85 10 V LwA 8 V LwA 6 V LwA 4 V LwA Air volume flow rate m3 s Input power P W Air volume flow...

Page 13: ...flue or roof penetration part Lift the fan from the enclosure lugs Pay attention to the lifting angle of the sling The lifting angle of the slings should be less than 50 MAX 50 A Mounting of the fan t...

Page 14: ...oof structures The roof penetration part includes a cable trough through which the feed and control cables can be led to the fan INSTALLATION DIMENSIONS A B C D Vallox Exxeo 150 380 255 370 240 Vallox...

Page 15: ...der the mounting frame must be smooth such as sheet metal The mounting frame is fastened to the supporting penetration structure with eight screws Masonry pipe or other penetration structure INSTALLAT...

Page 16: ...te freely and that there are no loose or extra objects inside the duct system or the roof fan Switch the fan on briefly to check its stable operation If everything is OK the roof fan can be started up...

Page 17: ...he risk of electric shock It contains capacitors that take time to discharge after the voltage is switched off Before working with the components make sure that there is no voltage Wait at least five...

Page 18: ...230 VAC 50 Hz max 16 A fuse L2 L3 N BN BU YE GN T3 T2 N Safety switch T1 L1 3 400 VAC 50 Hz max 16 A fuse BK GY Exxeo 2000 4100 Exxeo 150 1400 Cable included in delivery Cable included in delivery Cab...

Page 19: ...IN 11V OUT CO NC NO CO NC NO EXTL GND EXTH GND NTC1 GND NTC2 GND CTRL Display buttons EXT CTRL FAN OUT IN MENU SENSORS Relay Relay 0 10V TACHO A B GND ALARM STATUS P METER EXT CTRL SENSORS ALARM STATU...

Page 20: ...TER 24VAC VDC 0 10V 0 2000ppm 0 10V 0 50 C SENSORS NTC1 GND NTC2 GND TP1 TP2 Temperature Potentiometer Clock switch N L 1 2 3 230 VAC EXT CTRL EXTL GND EXTH GND Humidity CO2 RH TE 24V GND GND 0 10V IN...

Page 21: ...l panel BN BU YE GN N T1 T2 T3 Safety switch YE GN BU BN 6 1 2 3 Y E G N 2 1 3 BU BN N L3 L2 L1 A D B D Analog In 0 10V PWM MODBUS RS 485 L N BN YE GN BU 4120153 4120159 4118178 GND B A GND B A CTRL F...

Page 22: ...on box L3 L2 PE L1 N BN BU BN Y E G N YE GN BK GY BN BK GY YE GN YE GN BN BU BK GY N T1 T2 T3 Safety switch YE GN BU GY BK BN 6 1 2 3 4 5 6 2 1 5 4 3 BU BN N L3 L2 L1 4120154 4120159 4118174 4120157 G...

Page 23: ...NOTE Neutral wires their adequacy Cable with 7 poles safety switch L3 L2 N L3 L2 N E g from contactor control of a 2 speed 3 phase AC roof fan Cable included in delivery 1 230 VAC 50 Hz 4 2 6 10 8 Co...

Page 24: ...C 50 Hz Bypass thermal protectors or check their adequacy 2 x 3 phase supply PE connected to existing Cable with 7 poles safety switch Cable included in delivery 4 2 6 10 8 Connection instructions for...

Page 25: ...Dual Speed transformer 4118758 YE GN BU BN Fan YE GN 6 1 3 1 6 5 Cable included in delivery Cables included in delivery 2 2 950026 3 4 2 6 10 8 INTERNAL ELECTRICAL CONNECTION VALLOX EXXEO 150 DS AND...

Page 26: ...4120314 11 7 12 E1 D1 GND 10V 24V PORT2 PORT1 GND ID1 B D A D GND ID1 B D A D YE GN 4120154 6 5 YE GN 3 2 6 1 4 5 6 1 1 6 3 3 A1 A2 262 261 K2 A1 K1 261 262 A2 3 13 1 14 6 4 2 5 6 4 2 14 13 1 3 3 E1 2...

Page 27: ...078 7a Safety switch 948180 10h Vallox Exxeo potentiometer 986010 11f Vallox Exxeo temperature sensor for wall 986030 7b Safety switch Vallox Exxeo DS 948110 10i Vallox Exxeo clock switch 986020 11h V...

Page 28: ...er 949078 7a Safety switch 948180 10h Vallox Exxeo potentiometer 986010 11f Vallox Exxeo temperature sensor for wall 986030 7b Safety switch Vallox Exxeo DS 948110 10i Vallox Exxeo clock switch 986020...

Page 29: ...an operating voltage of 11 V for 0 10 V stepless control of the potentiometer Dimensions w x h x d 82 x 82 x 65 mm The potentiometer can be immersed in the outlet box IP44 or mounted on the wall surfa...

Page 30: ...asuring element NTC 10 Protection class IP54 Bushing seal M16 x 1 5 Measuring range 50 C 50 C Time constant 25 s Materials Box lid PC base PBT bushing seal PA Conduit Ms 8 mm length 250 mm Flange PA V...

Page 31: ...31 Vallox Oy All rights reserved...

Page 32: ...Vallox Oy All rights reserved D11341 10 11 2023 www vallox com Vallox Oy Myllykyl ntie 9 11 32200 LOIMAA FINLAND...

Reviews: