Low-energy ventilation unit 

with heat recovery

© Vallox
1.09.399B EN
Updatet
26.1.2015
Valid from:

26.1.2015

1   Supply air fan
2   Extract air fan
3   Post-heating radiator, electric, 

 

900 W (behind supply air heater)

4   Bypass duct heater, electric, 

 

900 W (only TSK Multi 80 MC, 

 

behind HR cell) 

5   Heat recovery cell
6   Outdoor air fi lter F7
7   Outdoor air fi lter G4
8   Extract air fi lter G4
9   Automatic summer/winter damper
10  Safety switch
11  Adjustment of relationship between 

 

supply and extract air

12  Adjustment of supply air 

 

temperature and 

 

summer/winter function

13  Speed selector switch (1-4) 

 (option)

13

Models 

TSK Multi 50 MC 3603

TSK Multi 80 MC 3602

Operating, maintenance and technical instructions

VALLOX TSK MULTI 50 MC

VALLOX TSK MULTI 80 MC

Electrical connection

230 V, 50 Hz, = 4.5 A

230 V, 50 Hz, = 8.8 A

Degree of protection 
provided by enclosures

IP 34

IP 34

Integrated direct-current fan
 

Extract air

0.043 kW  0.32 A  57 dm

3

/s  100 Pa  0.071 kW  0.5 A  93 dm

3

/s  100 Pa

 

Supply air

0.043 kW  0.32 A  49 dm

3

/s  100 Pa 0.071 kW  0.5 A  76 dm

3

/s  100 Pa

Heat recovery 

Cross-counter fl ow cell, 

 > 80%

Cross-counter fl ow cell, 

 > 80%

Heat recovery bypass

Automatic

Motorised damper

Electric post-heating unit

900 W, 3.9 A

max 900 W, 3.9 A

Bypass duct heater

-

900 W, 3.9 A

Filters
 

Supply air

G4 + F7

G4 + F7

 

Extract air

G4

G4

Weight

45.0 kg

58.5 kg

Ventilation power adjustment

SC controller, 0-10 VDC

SC controller, 0-10 VDC

Remote monitoring control 0-10 VDC

Remote monitoring control 0-10 VDC

Options

SC controller

SC controller

SlimLine PTXP MC cooker hood

SlimLine PTXP MC cooker hood

SlimLine PTXPA MC cooker hood

SlimLine PTXPA MC cooker hood

TECHNICAL DATA

MC

Vallox TSK

Multi 

50

80

1

12

10

11

9

8

7

5

6

3

4

2

AN

NU

AL E

FFICIENC

Y R

AT

IN

G

 O

F E

XT

RA

CT A

IR 

HEA

T R

EC

OV

ER

A

+

Summary of Contents for Vallox TSK Multi 50 MC R

Page 1: ...ction provided by enclosures IP 34 IP 34 Integrated direct current fan Extract air 0 043 kW 0 32 A 57 dm3 s 100 Pa 0 071 kW 0 5 A 93 dm3 s 100 Pa Supply air 0 043 kW 0 32 A 49 dm3 s 100 Pa 0 071 kW 0...

Page 2: ...ntact Vallox Maintenance Adjustment of relationship between supply and extract air This feature may be useful when adjusting air flows at the valves during mounting After the valves have been adjusted...

Page 3: ...Heat recovery cell When you replace the filters you are also advised to check the cleanliness of the heat recovery HR cell D at about two year intervals The G4 filters and their supports the sealing...

Page 4: ...xing screw of the fan housing 1 IUnfasten the fixing screw of the fan housing 2 Detach the connector bundle from the wall 3 Detach the connectors from each other 2 Pull the bypass duct filter stand bu...

Page 5: ...water needs to flow out from the ventilation unit without hindrance In carrying out maintenance for instance in autumn before the beginning of the heating season make sure that the condensing water ou...

Page 6: ...0 V 11 4 V 10 0 V 9 0 V 8 0 V 7 0 V 6 0 V 5 0 V 4 0 V 3 0 V Air flow dm3 s 54 6 50 4 43 9 38 7 31 3 25 1 18 8 13 8 8 1 62 8 56 9 50 3 45 0 37 9 32 1 26 2 19 1 13 7 Medium frequency of the octave band...

Page 7: ...he octave band Hz 63 60 4 60 4 57 4 56 0 54 3 52 4 55 8 43 3 43 2 55 6 55 0 57 7 54 5 48 5 47 3 48 4 39 8 38 9 125 64 5 61 9 60 4 58 5 56 9 54 6 52 4 46 1 39 1 60 1 58 3 56 8 53 7 50 9 48 3 48 0 41 6...

Page 8: ...ault signal relay 230V 50Hz DIP switch 1 2 3 4 5 6 7 8 9 1 2 3 4 5 1 2 3 4 Adjustment of freezing level Extract air NTC 1 Outdoor air NTC 2 Supply air to the dwelling NTC 3 Exhaust air NTC 4 Supply ai...

Page 9: ...alternative 54 Plug cord and cord for SC speed switch Space required for mounting H A L I T O T L O U H G E D B A C 61 43 27 47 SPACE FOR MAINTENANCE SPACE FOR MAINTENANCE B A Seen from above Right s...

Page 10: ...088410 8 Fan housing metal parts inlet cone partition and insulation 50 MC SC BP 3463100 3463200 3463300 8 Fan housing metal parts inlet cone partition and insulation 80 MC SC BP 3387410 3318210 34789...

Page 11: ...80 mm supply air 80 MC SC BP 3352700 27 G4 filter stand 400 mm extract air 50 MC SC BP 3382800 27 G4 filter stand 450 mm extract air 80 MC SC BP 3368500 28 G4 filter supply air 50 MC SC BP 978036 28 G...

Page 12: ...12 MC Vallox TSK MC MC Multi 50 80 VALLOX We reserve the right to make changes without prior notice What the units include can vary depending on the sales area 1 09 399bE 26 1 2015 PDF www vallox com...

Reviews: