4EXP70EN - 9/2023

The maximum filling air pressure for the dampener 

is 6 bar (0,6 MPa).

In case the process pipeline pressure is changed readjust 

the dampener pressure.

When a dampener is decommissioned, dispose the parts 

according to the local regulations and the instructions given 

by the part or device manufacturer.

Collect and dispose dangerous process media, so that people 

and environment are not endangered. Follow the local 

regulations.

 

Servicing and Maintenance

6.2  General maintenance and checks

 WARNING!

High pressure injection hazard.

Isolate the dampener completely from the process, 

depressurise and drain it before changing the hoses. 

Follow the factory safety regulations.

Do not step on the dampener installed in horizontal or 

angled position.

Only personnel with appropriate training are allowed to 

service the dampeners.

Check the condition of the dampener regularly. When the 

dampener actuates flawlessly, periodic inspection is the only 

mandatory maintenance task. Do not neglect it as hoses wear 

over time depending on conditions and process. 

Scheduled maintenance

Include the dampeners in your factory maintenance program. 

Maintenance tasks and service intervals are offered as a 

guideline in Table 4. Schedules will vary with applications.

Table 4. 

Maintenance schedule.

Maintenance task

Frequency & advice

Check the dampener pressure.

Every month.

Check the dampener doesn’t hit 

anything and there’s no leakage.

Every month.

Spare parts

To ensure correct and quick delivery of spare parts, the order 

must contain the following information:
•  Dampener type number as in type plate (example: 

FPD65-10-0-2-NR)

•  Spare part name and quantity (example: Damping Hose, 

1 piece)

You can order the spare parts from Valmet's Flow Control 

offices, distributors or agents. Contact information is available 

at https://contact.neles.com/
It is recommended to keep 1 set of hoses and clamps as spare 

parts at your factory warehouse. For part numbers refer to 

figures 1 and 2.

6.3  Changing the hoses

To change the hoses, the dampener needs to be removed 

from the pipeline. Part numbers refer to 

Figures 1 and 2.

 WARNING!

High pressure injection hazard.

Do not disconnect a pressurized dampener from the 

pipeline for any reason.

Removing the hoses

1.  Shut down the pump and lock it to OFF position.
2.  Depressurise and drain the pipeline according to factory 

specific orders.

3.  Depressurise the dampener with the valve (part 7) on the 

hose flange.

4.  Loosen the flange connections and lift the dampener 

to a suitable working surface. Use lifting equipment on 

dampeners weighing over 25kg.

Summary of Contents for Flowrox Expulse Series

Page 1: ...tion and maintenance instructions for Flowrox Expulse Dampener DN32 DN100 These instructions must be read carefully and understood prior to the installation use and servicing of this product Installat...

Page 2: ...NG THEIR FUNCTIONS EVERYONE MUST BECOME FAMILIAR WITH ALL INSTRTUCTIONS IN THIS MANUAL BEFORE ANY INSTALLATION USE MAINTENANCE REPAIR OR ANY OTHER ACTIONS OF THE RESPECTIVE GOODS AND OR SERVICES WHICH...

Page 3: ...over Table of Contents 1 EU DECLARATION OF CONFORMITY 4 2 General safety instructions 5 3 Introduction 5 3 1 Applications and purpose of use 5 3 2 General description 6 3 3 Technical data 8 4 Transpor...

Page 4: ...n dampener size range DN32 DN100 is in conformity with the European Community s Directive PED 2014 68 EU Categorization Category I Properties of fluid PED Article 13 Fluid group 2 Conformity assessmen...

Page 5: ...ired to observe the IOM manual in all work tasks for the dampener Use personal protective equipment when performing any checks or maintenance operation for the inline pulsation dampener goggles helmet...

Page 6: ...ampener provides full bore through which the medium can travel The main components are shown in Figure 1 and Figure 2 The dampening effect can be adjusted with the air pressure Normally the needed pre...

Page 7: ...of DN80 and DN100 Flowrox Expulse dampener Part Description Part Description 1 Damping hose 7 Valve 2 Cover hose 8 Plug 3 Pulsation hose connector 9 Lock nut 4 Pulsation hose flange 10 O ring 5 Hose...

Page 8: ...etc 4 Nominal diameter pressure class Table 3 Expulse dampener model key table Type Size DN Pressure class PN Flanges Con nector Flange Connector material Wetted parts material FPD Flowrox Pulsation...

Page 9: ...rom the cover hose part 2 Use soft straps for lifting as shown in Figure 4 Lifting example Figure 4 Lifting example Do not attach lifting equipment to the bore as it can damage the dampener For Expuls...

Page 10: ...equipment 2 Apply pipe tape or hemp on the connector threads 3 Tighten the connectors between the dampener and pipeline Figure 7 Maximum dimension between the pipeline center axes Dim X 1 x DN size f...

Page 11: ...are offered as a guideline in Table 4 Schedules will vary with applications Table 4 Maintenance schedule Maintenance task Frequency advice Check the dampener pressure Every month Check the dampener d...

Page 12: ...part 5 on the cover hose part 2 7 Remove the cover hose part 2 8 Remove the lock nuts 9 pulsation hose flanges part 4 and o rings 10 Figure 10 Removing the lock nuts 9 pulsation hose flanges part 4 a...

Page 13: ...ghtening instructions are not given Part numbers in these assembly instructions refer to figures 1 and 2 Table 5 General tightening torques bolt class 8 8 lubrication MoS2 Size M6 M8 M10 M12 M16 M20 M...

Page 14: ...rs Figure 14 Installing the o rings 3 Install one pulsation hose flange part 4 and plug part 8 to the other end of the dampener 4 Install the lock nut part9 on the pulsation hose flange Figure 15 Inst...

Page 15: ...Table 6 Troubleshooting Problem Possible reason Action Leakage from connection Connector is loose Tighten the connector If needed add pipe tape or hemp fiber to the connection Hose lifetime is short O...

Page 16: ...kg Max Pressure Bar 32 1100 40 G1 1 4 Threads 7 10 40 1100 50 G1 1 2 Threads 11 10 50 1400 63 G2 Threads 13 10 65 1500 76 G2 1 2 Threads 18 10 80 1500 102 G3 Threads 38 10 100 2000 115 G4 Threads 55...

Page 17: ...17 4EXP70EN 9 2023...

Page 18: ...4EXP70EN 9 2023 18...

Page 19: ...19 4EXP70EN 9 2023...

Page 20: ...Stonel Valvcon and Flowrox and certain other trademarks are either registered trademarks or trademarks of Valmet Oyj or its subsidiaries in the United States and or in other countries Valmet Flow Con...

Reviews:

Related manuals for Flowrox Expulse Series