15
4EXP70EN - 9/2023
Figure 16. Installing the cover hose.
6. Install the second pulsation hose flange (part 4) and
valve (part 7).
7. Install the lock nut (part 9) on the pulsation hose flange.
8. Install the hose clamps (part 5) to the dampener.
Figure 17. Installing the pulsation hose flange and hose
clamps.
6.4 Troubleshooting
Table 6.
Troubleshooting.
Problem
Possible reason
Action
Leakage from connection
Connector is loose
Tighten the connector. If needed add pipe tape or hemp fiber to the connection.
Hose lifetime is short
Overpressure in dampener
Adjust the air pressure according to the instructions in commissioning chapter
Dampener does not
decrease vibrations /
pressure variation
Dampener pressure not correct
Adjust the air pressure according to the instructions in commissioning chapter
Damaged hose
Check and change damaged parts