9
4EXP70EN - 9/2023
4 Transportation, Storage and
Lifting
Check and document any damages in the transport packages
or dampeners. Contact the transportation company in case of
damage. When new or unused dampeners are sitting idle for
long periods, the following procedures should be complied
with:
1. Prior to storage, thoroughly drain dampeners of any and
all water.
2. Indoor storage is required. For unfavourable
environment, cover the equipment with protective
tarpaulin that will allow proper air circulation.
3. Protect the equipment from temperature and humidity
extremes and exposure to excessive dust, moisture,
vibration, sunlight, ozone and solvents.
4. Cover the flange openings.
5. Do not store any objects on top of the rubber hoses.
6. Before operation clean the dampener.
When storing used dampeners, wash them with fresh water
and follow the steps above. For storage periods greater than
36 months, please contact Valmet Flow Control as the rubber
parts need to be changed before use.
Lifting equipment must be used for dampeners weighing
over 25kg.
Lift the dampeners securely from the cover hose (part 2). Use
soft straps for lifting as shown in Figure 4. Lifting example.
Figure 4. Lifting example.
Do not attach lifting equipment to the bore as it can damage
the dampener. For Expulse™ dampener dimensions and
weighs refer to
Appendix A
.
5 Installation
WARNING!
High pressure injection hazard.
Do not use higher pressure than rated for the dampener.
Higher pressures can cause serious damage to the
equipment and harm to operating personnel.
Do not pressurise the pipeline before the dampener is
properly installed.
Do not install the Flowrox Expulse™ dampener on the
feed side of a pump. The dampener is not designed to
work under vacuum may be damaged.
Do not twist or rotate the dampener with any tools if the
other end is attached to a pipeline. The dampener can be
damaged.
5.1 General
Flowrox Expulse™ inline pulsation dampeners are normally
delivered fully assembled and ready for use. Only personnel
with appropriate training are allowed to install the
dampeners.
If the dampener is delivered disassembled it must
be assembled in accordance with the manufacturer’s
instructions.
Flowrox Expulse™ dampeners include connections with
threaded connectors.
Reserve enough space for safe installation and maintenance.
See
Appendix A
for Expulse™ dampener dimensions.
Summary of Contents for Flowrox Expulse Series
Page 17: ...17 4EXP70EN 9 2023...
Page 18: ...4EXP70EN 9 2023 18...
Page 19: ...19 4EXP70EN 9 2023...