The appliance is supplied with two fireback
spacers.
Do not fit the fireback spacers if the
fire is to be installed into a precast or clay flue
block system as in section 4.2.3
. These should
extend backwards to ensure sufficient clearance
from the back of the fireplace. Remove the label
and retaining screws from the rear sides of the
hotbox. Position the fireback spacer as shown in
figure 13. Secure the fireback spacers using the
screws removed previously and the two supplied
with the fire.
14.
This appliance is supplied with a flue
restrictor for use where the flue draught is
excessive. The restrictor must NOT be fitted
where a precast flue or a flue liner is used. For all
other installations the restrictor should be fitted.
There may however, be certain exceptional
circumstances where fitting the
restrictor causes the fire to fail the
spillage test. In such cases the
restrictor will have to be removed.
After removal conduct the spillage
check again.
The restrictor is packed loose with
the appliance and is fixed with two
screws. See figure 14
.