![background image](http://html2.mh-extra.com/html/valor/1100in/1100in_danger-a-barrier-designed-to-reduce-the-risk-of-burns-from-the-hot-viewing-glass-is-provided-with-th_3277483031.webp)
31
*
Appr
o
x
.
49-3/4”
(1266 mm) with 12”
v
e
nt pipe
40”
(1016 mm) t
o
underside of c
ombustible ca
vit
y
Min 1”
(25.4 mm)
Required
clearance
to vertical
pipe affects
cavity depth
12” pipe section
Appr
o
x
. 39-1/4”
(997 mm)
Stand-off
Fireplace -
Left Side View
40”
(1016 mm) t
o
underside of c
ombustible ca
vit
y
1/2”
(13 mm)
beyond
stand-off
Appr
o
x
. 31”
(787 mm)
*
Appr
o
x
. 42-1/4”
(1073 mm)
*
Appr
o
x
. 52-3/4”
(1340 mm) with 12”
v
e
nt pipe
Fireplace -
Left side view
12” pipe section
Venting Considerations—Vertical Takeoff
Venting Considerations—Horizontal Takeoff
*
Notes—ALL venting considerations
• Dimensions of venting are based on
using Dura-Vent elbows. Elbow curve
radius dimensions will vary when using
other brands. In general, other brands
have slightly bigger radius.
• 3 inches clearance to combustibles
required above horizontal pipe. Slope
horizontal pipe upwards 1/4 inch per foot.
1 inch clearance required around sides
and bottom of horizontal pipe and around
vertical pipe.
• When calculating effective pipe lengths
subtract approximately 1-1/2 inch for
pipe joint - for example, a 12 inches pipe
section will add approximately 10-1/2
inches overall.
Framing Requirements
QUALIFIED
INSTALLER