background image

3

4.  If necessary, thread the power cord around the back 

of the firebox post as indicated. 

5.  Plug the power cable into the receptacle—only after 

the other connections mentioned earlier are 

complete! An green LED light indicates the 

V-module is powered..

6.  Test the fan operation before reinstalling the 

burner. See “Test Fan Operation” on page 4 .

7.  Use the self-adhesive wire clamp provided to secure 

the cable between the fan and the control module 

to the base of the fireplace. 

Install Fan Into Fireplace

The V-module, power cord and junction box should 

already be installed in the firebox as part of the 

standard accent lighting supplied with the fireplace. If 

not, see the fireplace’s installation manual for details on 

how to install them. 
The V-module will also control the fan. First ensure 

power is disconnected from the V-module by unplugging 

it from the junction box.
1.  Install the fan into the fireplace.

a.  Slide the fan inside the fireplace case and push 

it as far back as possible so that the threaded 

studs at the bottom of the fireplace fit tight 

against the end of the slots in the fan mounting 

plate. 

b.  Secure the plate with two nuts provided.

2.  Apply provided self-adhesive wiring diagram label 

to the fan mounting plate between its fixing studs.

3.  Plug the fan relay cable into the “FAN” terminal of 

the V-module. 

Front of 

fireplace

Power cord around 

back of firebox post

Fan control 

module 

(v-module)

Plug fan relay cable 

to control module 

Control 

module 

wire to 

receiver

Fan 

mounting 

plate

View looking left from inside 

fi

 rebox 

(burner 

module plate removed). Fan control module 

(v-module), power cord and fan control module 

wire provided with the 

fi

 replace. 

Summary of Contents for 1495CFK

Page 1: ...burner module and gas train from the fireplace The fan is designed to operate on and off automatically when the burner comes on and off The fan speed can be controlled from the remote control handset...

Page 2: ...MO TE CO NT RO L RE CE IVE R SH IPP ED WI TH FIR EP LA CE V M OD UL E CO NT RO L SH IPP ED WI TH FIR EP LA CE JU NC TIO N BO X WI TH RE CE PT AC LE WI TH IN FIR EP LA CE SH IPP ED WI TH FIR EP LA CE...

Page 3: ...l them The V module will also control the fan First ensure power is disconnected from the V module by unplugging it from the junction box 1 Install the fan into the fireplace a Slide the fan inside th...

Page 4: ...fireplace s components Pay careful attention to all pipes and wires under the module plate to ensure they are not damaged in the process of re installation Test Fan Operation The fan is normally oper...

Page 5: ...TH FIREPLACE V MODULE CONTROL SHIPPED WITH FIREPLACE JUNCTION BOX WITH RECEPTACLE WITHIN FIREPLACE SHIPPED WITH FIREPLACE POWER CORD SHIPPED WITH FIREPLACE WARNING Electrical Grounding Instructions Th...

Page 6: ...du ventilateur sont s lectionn es et programm es avec la manette de la t l commande Le ventilateur a quatre vitesses Il d marre toujours en vitesse maximale et s ajuste ensuite la vitesse programm e I...

Page 7: ...TO RS RE MO TE CO NT RO L RE CE IVE R SH IPP ED WI TH FIR EP LA CE V M OD UL E CO NT RO L SH IPP ED WI TH FIR EP LA CE JU NC TIO N BO X WI TH RE CE PT AC LE WI TH IN FIR EP LA CE SH IPP ED WI TH FIR...

Page 8: ...ntilateur au fond du foyer en le poussant le plus en arri re possible de fa on ce que les chevilles filet es du fond de la caisse soient ins r s le plus en avant possible dans les fentes de la plaque...

Page 9: ...ateur allum et indicateur de vitesse Bouton du ventilateur PM PM R DUIRE LA VITESSE OU ARR T AUGMENTER LA VITESSE Op ration normale Les directives d utilisation du ventilateur sont incluses dans la se...

Page 10: ...DE L QUIPEMENT ORIGINAL DU MANUFACTURIER MOD LE 1495CFK VENTILATEUR DE CIRCULATION D AIR 120 VAC 60 HZ MOINS D UN AMP RE FABRIQU POUR MILES INDUSTRIES LTD NORTH VANCOUVER BC CANADA 4009245 01 FIL DE...

Reviews: