30
Install Electrical Wiring (if required)
This section provides information to install the electric
pre-wiring required for use with the optional GV60WIFI
WiFi Kit.
All wiring must be done by a quali
fi
ed electrician in
accordance with local codes or, in the absence of local
codes, with the
National Electrical Code, ANSI/NFPA 70
or
the
Canadian Electrical Code, CSA C22.1
.
Electrical Requirements
GV60WIFI—6 VDC (from receiver), less than 1 amp
General Requirements
The optional GV60WIFI kit requires a GV60VM power
supply (known as a V-Module), which includes a three-
prong grounded plug to plug into a grounded recepta-
cle installed within the
fi
replace enclosure by a quali
fi
ed
electrician.
The receptacle, housing, and strain relief are supplied
and installed as part of the
fi
replace.
Notes
• We recommend connecting the electrical box even
if the optional kit has not been purchased. It is much
easier to wire before wall
fi
nish is applied.
• Wiring within the receptacle enclosure must have a
minimum 90°C temperature rating.
• Wire nuts not included.
Installation
1. Locate the electrical housing. It is behind the front
panel of the
fi
replace in the bottom right corner.
2. Remove the inner cover (2 screws).
3. Pull the inner cover and receptacle (attached) out of
the
fi
replace.
Inner
Cover
Receptacle
Grounding
Stud
Outer
Cover
Strain
Relief
Installation
Electrical Wiring