background image

Spare Parts

Code

Description

Part 

Number

1

Exhaust Slide Assembly

4002287

2

Exhaust Slide Gasket

4000176

3

Restrictor enclosure

4002330

4

Metal strip

4002329

5

Restrictor assembly

4002707

6

Coil spring

4002605

7

Rod support

4002331

8

Valve access cover

4002289

9

Side brick anchors (2)

4001283

10

LH Explosion relief assembly

4001286

11

RH Explosion relief assembly

4001287

12

Shrouds (2)

4002446

13

Burner module assembly NG

4002257S

Burner module assembly LPG

4002258S

14

Ceramic burner platform

4002573

15

Window frame assembly 

(inc. glass)

4002259

16

Access panel gasket

4002664

17

Access plate

4002510

18

Top gasket

4002403

19

Side gaskets (2)

4002404

20

Bottom gasket

4002405

21

Sealing gasket

4001363

22

Pipe gaskets (2)

4002595

23

Elbow connector

4002355

24

Pipe support

4002508

25

Front pipe assembly

4002485

26

Thermocouple interrupter

4001037

26a Inlet brass connector

4000746

27

GV60 valve

4000873X

28

Switch bracket

4002566

29

34” flex pipe

4002475

30

Solenoid

4002250

31

Rear pipe assembly

4002486

32

Pilot Assembly NG

4000735

Pilot Assembly LPG

4001691

33

Thermocouple

4000061

34

Pilot Injector #51 NG

4000735

Pilot Injector #30 LPG

4000736

35

Pilot Tube

4000732

36

Pilot Hood 2 Flame

4000730

37

Extended Nut

4001855

Code

Description

Part 

Number

38

Electrode

4001856

39

Insulation sleeve for ignition cable

4002244

40

Injector nut

420K464

41

Air shutters (2)

4002590

42F

Front - Injector elbow #500 NG

4002606

Front - Injector elbow #150 LPG

4002867

42R

Rear - Injector elbow #360 NG

4002607

Rear - Injector elbow #280 LPG

4002866

43

Auxiliary battery holder

4002249

44

Ignition Cable

4001039

45

Switch with Cable

4001036

46

Cable Interrupter

4001035

47

Receiver

4002422

48

Remote Control Handset ‘Max’

4002251

49

Wiring Harness

4001187

50

Remote Control Wall Holder

9000008

51

Log Set Complete

4002610

52

RH middle log

4002683

53

RH base log

4002685

54

Center base log

4002686

55

LH base log

4002684

56

LH middle log 

4002682

57

LH cross log

4002680

58

Rear log

4002681

59

RH cross log

4002679

60

Liner panels—complete set

a

Ledgestone

786LSL

b

Enamel black

787EBL

c

Ceramic fluted black

788FBL

d

Valor red brick

789VRL

61

Top panel

a

Ledgestone

4002368

b

Enamel black

4002374

c

Ceramic fluted black

4002374

d

Valor red brick

4002385

62

Rear panel

a

Ledgestone

4002367

b

Enamel black

4002373EB

c

Ceramic fluted black

4002379

d

Valor red brick

4002384

34

Summary of Contents for 785ILN

Page 1: ...domestic room heating appliance It must not be used for any other purposes such as drying clothes etc This appliance is suitable for installation in a bedroom or bed sitting room Manufactured by MILES...

Page 2: ...l your dealer immediately Do not try to repair the unit as you may cause an injury or damage the fireplace The information contained in this installation manual is believed to be correct at the time o...

Page 3: ...einstall 15 Ceramic Panels Installation 15 Ceramic Logs Installation 16 Window Refitting 18 Remote Control Initial Set up 19 Operation Check Aeration Settings Adjustment 20 Side Shrouds Installation 2...

Page 4: ...ration Due to the high temperature the appliance should be LOCATED out of traffic areas and away from furniture and draperies Clothing or flammable material SHOULD NOT BE PLACED on or near the applian...

Page 5: ...rdance with the current ANSI Z223 1 and or local codes having jurisdiction Heating value of gas in some areas is reduced to compensate for elevation consult your local gas utility to confirm For insta...

Page 6: ...appliance is NOT APPROVED for installation with a zero clearance kit 785IL fireplace Chimney Terminal Cap Flashing 2 x 3 approved flex chimney liners running full length Existing unaltered functioning...

Page 7: ...fan power cord outlet 6 1 9 m Fan power cord Trim sold separately Valve access panel X Y Dimensions Cavity Check that masonry step does not interfere with install dimensions or vent pipe If mantel is...

Page 8: ...ls that bear the UL mark for zero 0 fire rating Sidewall Clearances Minimum distance from side of appliance liner box to combustible wall 9 229 mm Mantel Projection A 1 25 mm 4 101 mm 8 203 mm 14 355...

Page 9: ...rbed airflow hits the outside vent terminal from any direction Check local codes for allowable vertical vent termination Venting Table Maximum vertical height 40 ft measured to bottom of termination M...

Page 10: ...inserting the 785IL into an existing fireplace cavity Generally no modifications are allowed to the existing fireplace that will compromise the integrity of the existing fireplace Components that are...

Page 11: ...ccess hole of 1 5 inch 38 mm or less through the lower sides or bottom of the firebox The access hole must be plugged with non combustible insulation after the gas supply line has been installed See D...

Page 12: ...e installed before the appliance is fitted into the cavity Refer to instructions provided with the 795CFK to install the fan Window Removal The window is held in place by a spring loaded lever on each...

Page 13: ...owards the back of the firebox 3 Apply RTV sealant to the collars on the vent slider and fit the two liners ensuring that the exhaust liner is connected to the identified EXHAUST vent collar Secure wi...

Page 14: ...g its equipment shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi 3 5 kPa Failure to either disconnect or isolate the appliance...

Page 15: ...Rotate the anchor back down to hold the panel The ceramic panels can be installed without removing the burner However you can remove the burner for additional space if desired 1 Remove the 2 screws f...

Page 16: ...ating its right hand end over the key in the ember bed Slide the log back until it rests against the vertical sheet metal edge 2 Place the left hand middle log in front of the rear log locating it ove...

Page 17: ...e the right hand base log locating its notch on the key in the ember bed as indicated 6 Place the right hand middle log locating its notch on the key in the ember bed as indicated 7 Place the left han...

Page 18: ...and release it to ensure the springs return it 4 Apply light hand pressure against the window frame sides to bed in the window seal Window frame Bottom railing Ceramic Logs Installation 8 Place the r...

Page 19: ...x Place the battery box upside on the left of the firebox Battery box connection Reset button Battery box Remove cover Connect battery box to wire 5 With a sharp object press and hold the receiver s r...

Page 20: ...low the unit to warm up for 10 15 minutes to evaluate the flame picture Burners are equipped with an adjustable shutter to control primary aeration See the figures below The shutters are factory set t...

Page 21: ...th the kit See the diagram below for required hardware and configurations Note that the holder can be installed at the base of a light switch plate IMPORTANT The location of the remote control handset...

Page 22: ...ength of the glass An emulsion type cleaner is recommended Use a soft damp cloth to apply the cleaner Dry the glass with a soft dry preferably cotton cloth Most paper towels and synthetic materials ar...

Page 23: ...and one 9 V alkaline battery for its handset Batteries should last one to two seasons depending on usage Removing the batteries in the off season will extend the battery life Should the batteries loo...

Page 24: ...from the remote handset and turn off the gas valve using the manual ON OFF switch Pilot Automatic Shut off The remote control system is equipped with safety features allowing it to shut the fire down...

Page 25: ...ng your fireplace OFF 1 Press the small flame button to reduce the flame to pilot 2 Press the OFF button to turn the pilot off Alternately you can press the O button on the switch if you won t use you...

Page 26: ...ically adjusted to achieve the Daytime set temperature temp TEMP MODE Nighttime Setback Temperature Mode appliance must be in Standby mode pilot ignited The room temperature is measured and compared t...

Page 27: ...perature control to turn off decrease the temp MODE setting until appears on the display Your fireplace will reach the set temperatures and the remote handset will check the temperature every five min...

Page 28: ...hen briefly press SET to P1 and set the stop time in the same manner you just set P1 4 Briefly press the SET button again for the next burner cycle time which will be P2 and P2 5 Once all four times a...

Page 29: ...etail stores carrying safety products for children Automatic Turn Down No communication If there is no transmission from the handset to the receiver within a 6 hour period the appliance will go to Sta...

Page 30: ...f you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 3 AUTOMATIC IGNITION g 1 Locate the pilot g 3 inside of rebox at Left Hand side O...

Page 31: ...Wiring Diagram Remote Battery Box Optional Fan 795CFK Control Module Optional Wall Switch Kit 1265WSK Latching Solenoid Valve Red Yellow 4 AA Batteries GV60 Wiring Diagram Connector 31...

Page 32: ...nector 46DVA ADF Co axial to Co linear Adapter 46DVA GCL TM 4CAA Co linear to Co axial Adapter 46DVA GK TM 4CTA Aluminum Flexible Liner 3 diameter 2280 Series 3 ACFL NOTE 2 ply liner approved to CAN U...

Page 33: ...or air from other household equipment or appliances iii Damage due to chemicals dampness condensation or sulphur in the fuel supply lines which exceeds industry standards i This warranty does not cove...

Page 34: ...le 4000061 34 Pilot Injector 51 NG 4000735 Pilot Injector 30 LPG 4000736 35 Pilot Tube 4000732 36 Pilot Hood 2 Flame 4000730 37 Extended Nut 4001855 Code Description Part Number 38 Electrode 4001856 3...

Page 35: ...Left side panel a Ledgestone 4002365 b Enamel black 4002371EB c Ceramic fluted black 4002377 d Valor red brick 4002382 64 Right side panel a Ledgestone 4002366 b Enamel black 4002372EB c Ceramic flute...

Page 36: ...Spare Parts 43 44 45 46 47 48 49 50 60 61 62 63 64 51 58 59 57 56 55 54 53 52 1 2 3 7 8 9 10 12 14 15 13 11 16 24 23 25 26 26a 17 18 19 19 21 22 20 32 38 42 F R 40 41 27 28 30 29 31 9 39 36...

Page 37: ...NG natural gas LPG propane Serial No Front Trim code description e g 790FTV Floating Trim Kit Vintage Iron Purchase date mm dd yyyy Home Owner Name Address City Province State Postal Code Zip Phone E...

Page 38: ...Product Postage needed Were you given all documentation and manuals for your product YES NO Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC V7H 3B1 Canada Fold here Online Warranty...

Reviews: