Figure 65. Burner injector removal
Figure 64. Flow rate controller
16.12
To Remove the Gas Flow Rate Controller
See figure 64.
1.
Remove the burner unit - See
section 16.6.
2.
If lying the burner on its back,
unscrew and remove the two ceramic
support brackets from the top of the
burner unit. This will avoid damage
to the brackets and the worksurface
(see figure 59)
3.
Detach the microswitch cover -
See section 16.1 paragraph 2.
4.
Detach the shut-off tap as detailed
in section 16.11 paragraphs 2-6.
5.
Detach the burner pipe from the
controller. Support the controller
while detaching to prevent excessive
strain.
6.
Remove the nut and washer
securing the control pivot bracket to
the controller at the front. Support
the pivot bracket while removing the nut
to prevent possible damage to the
microswitch.
7.
Remove the hexagonal bolt securing
the control pivot bracket to the controller
at the rear.
8.
Detach the control pivot bracket.
9.
Remove the hexagonal nut securing the
controller to the front mounting bracket
and remove the flow rate controller.
10.
Refit in the reverse order.
16.13
To Remove the Main Burner Injector
See figure 65.
1.