WARNING
This conversion kit shall be installed by
a qualified service agency in accordance
with the manufacturer’s instructions and
all applicable codes and requirements
of the authority having jurisdiction. If
the information in these instructions is
not followed exactly, a fire, explosion
or production of carbon monoxide may
result causing property damage, personal
injury or loss of life. The qualified service
agency is responsible for the proper
installation of this kit. The installation
is not proper and complete until the
operation of the converted appliance is
checked as specified in the manufacturer’s
instructions supplied with the kit.
Use this manual in conjunction with the
installation manual supplied with the
appliance.
1000NGK / 1000PGK Gas Conversion Kit
Use with Valor H3 1000J, 1000K Heater Models ONLY
INSTALLATION MANUAL
H3 Series
4007648-03
©2021, Miles Industries Ltd.
Kit Contents
• 1 Pilot injector
• 1 Main burner injector elbow
• 1 Air shutter
• 1 Pilot shield
• 1 Minimum rate bypass screw
• 1 Set of conversion labels
Tools Required
• Wrenches, to disconnect gas line
• Phillips (+) screwdriver, to remove burner module
• Small (jewelers size)
fl
at blade screwdriver, to set pres-
sure
• Small
fl
at blade screwdriver, to release pressure tap
on valve
• Needle nose pliers, to remove bypass screw
• Hex (Allen) wrench, 4 mm or 5/32”, to remove pilot
injector
• Manometer, to set pressure
Speci
fi
cations
* This appliance is certi
fi
ed for use from 0–4500 feet. For
altitudes above 4500 feet, see local codes.
Model
1000JN
1000KN
1000JP
1000KP
Gas
Natural
Propane
Altitude (Ft.)*
0-4,500 feet*
Input Maximum (BTU/h)
25,000
24,000
Input Minimum (BTU/h)
12,000
11,000
Manifold Pressure (in w.c.)
3.2”
9.5”
Minimum Supply Pressure (in
w.c.)
5”
11”
Maximum Supply Pressure (in
w.c.)
10”
14”
Main Burner Injector Marking
750
260
Pilot Injector Marking
51
30
Min. Rate Bypass Screw
175
105