Replace the Pilot Injector
1. Remove the pilot shield if installed (2 screws).
2. Remove the pilot hood by releasing the U-clip and
pulling up on the hood. The U-clip should not be
removed.
3. Unscrew the pilot injector using an Allen key. Dis-
card the old pilot injector.
4. Replace with the appro-
priate pilot injector—see
Specifications
table on page
1; the pilot injector number
is stamped on the barrel.
Screw in the new injector.
5. Re
fi
t the pilot hood by
pushing down on it, mat-
ing its notch and key at the
base. Ensure that it snaps
into position.
Pilot hood
U-clip
7.
Air shutter stopper, if equipped.
This part is no longer necessary. If the appliance has
an air shutter stopper, remove the 2 screws retain-
ing it, discard it and reinstall the 2 screws to plug the
holes. This part is no longer used.
Test Air Shutter Movement
Under the burner plate, locate the air shutter lever and
slide it from left to right to ensure it is moving freely.
If appliance equipped
with air shutter
stopper, remove
and discard. Re-use
screws to plug holes.
Air shutter stopper
removed
Notch
Key