1
Description of System
The model listed above has been designed to accommo-
date the installation of this air circulation fan.
Operated via the remote control handset and having
variable speed control, the fan is designed to boost the
natural convection through the heater; this may be a
desirable feature dependent on the fireplace location
and room layout.
It is preferable to install the circulating fan before
completing the heater installation
, although it may
also be retrofitted at a later date. A junction box and
receptacle for powering accent lighting are supplied
as standard equipmentwith the 1400M fireplace. This
optional 1495CK Circulating Fan Kit is intended to utilize
the same power supply as the accent lighting. Therefore
a separate power supply is not required.
Ensure the power for the accent lighting has been in-
stalled before proceeding. Otherwise, see the fireplace’s
Installation Manual to set it up.
1495CFK Circulating Fan Kit
Approved for use with Valor fireplace models 1400M only
4009243-01
© 2022, Miles Industries Ltd. All rights reserved.
Retrofitting the fan after the fireplace installation is com-
pleted will require disconnecting the gas and removing
the burner module and gas train from the fireplace.
The fan is designed to operate on and off automatically
when the burner comes on and off. The fan speed can
be controlled from the remote control handset. There
are four speeds available. The fan, if turned on, will start
approximately 4 minutes after lighting the fireplace and
will continue to run for approximately 10 minutes after
the burner is shut off, and the control valve has rotated
all the way to “OFF”. The fan will operate at the speed
last selected by the user.
Electrical Requirements
The fan kit requires a power supply of
120 Volts,
1 phase, 60 Hz. Full load current is less than 1 amp.
INSTALLATION MANUAL
H6 1400M
WARNING
If these instructions are not followed
exactly, a fire or explosion may result
causing property damage, personal
injury or loss of life.
WARNING
Live wiring must terminate within
a junction box. A junction box is
supplied with the fireplace.
WARNING
The power supply must be installed
and grounded in accordance with
local codes, or in the absence of local
codes, with current
Canadian Electrical
Code
CSA C22.1, or, in the USA the
National Electrical Code
ANSI/NFPA70
latest edition.
NOTE
This kit must be installed or serviced by
a qualified installer, service agency or
gas supplier. These instructions are to
be used in conjunction with the main
installation instructions for the above
listed fireplace models.