background image

Models

 

1500NG
1600NG

1500LPG 1600LPG

Gas

Natural

Propane

Propane

Altitude (Ft.)*

0-4,500 feet*

Input Maximum (Btu/h)

30,000

28,000

26,000

Input Minimum (Btu/h)

18,000

18,500

18,500

Manifold Pressure (in w.c.)

4.0

9.5

10.0

Minimum Supply Pressure 

(in w.c.)

5.0

11.0

11

Maximum Supply Pressure 

(in w.c.)

10.0

14.0

14

Main Burner Injector 
Marking

850

300

260

Pilot Injector Marking

51

30

30

Min. Rate By-Pass Screw

220

160

160

WARNING

This conversion kit shall be installed by a 
qualifi ed service agency in accordance with 
the manufacturer’s instructions and all appli-
cable codes and requirements of the authority 
having jurisdiction. If the information in these 
instructions is not followed exactly, a fi re, ex-
plosion or production of carbon monoxide may 
result causing property damage, personal in-
jury or loss of life. The qualifi ed service agency 
is responsible for the proper installation of this 
kit. The installation is not proper and complete 
until the operation of the converted appliance 
is checked as specifi ed in the manufacturer’s 
instructions supplied with the kit.

Use this manual in conjunction with the instal-
lation manual supplied with the appliance.

General notes regarding conversion

The conversion may be done before or after the 
appliance is installed into the cavity. Ideally before 
the wall fi nish is applied, otherwise the burner 
module must be removed. The gas must be 
connected in order to set the manifold pressure.

Prepare the appliance

1.  If the fi replace is already installed, remove the 

side hinged doors, plinth, window, fuel bed, 
platform, and platform middle supports.

2.  Disconnect the gas inlet pipe from the inlet 

elbow fi tting on the valve.

L1 Series

4002880-04

Gas Conversion Kit

1500-1600NGK, 1500PGK, 1600PGK

Installation Instructions

This appliance is certifi ed for use from 0–4500 feet. For 
altitudes above 4500 feet, see local codes.

Kit Contents

1 Pilot injector
1 Main burner elbow injector
1 Set of conversion labels
1 Air shutter (NG only)
1 bypass screw
1 burner injector gasket

Tools Required

•  Wrenches, to disconnect gas line
•  Phillips (+) screwdriver, to remove burner module & 

pilot shield

•  Small (jewelers size) fl at blade screwdriver, to set 

pressure

•  Small fl at blade screwdriver, to release pressure tap 

on valve

•  Needle nose pliers, to remove by-pass screw
•  Hex (Allen) wrench, 4 mm or 5/32”, to remove pilot 

injector

•  Manometer, to set manifold at the valve

Specifi cations

Use with 

Valor Models 1500 and 1600 Heater ONLY

© Copyright Miles Industries Ltd., 2017