Venting Installation
IMPORTANT: This appliance’s venting system is room sealed and
therefore, does not require room air to be used in the combustion process.
1. Rough-in two 3” diameter vent liners into the existing chimney
system from the roof. Be careful not to tear or damage the liners in
the process. It may be easier to install both liners at the same time
rather than one at a time. Leave plenty of liners at the bottom to
facilitate the connection of the liners to the vent slider.
It is best to
leave the top termination until later.
Designate and mark the top and bottom of one liner as
“EXHAUST” to avoid confusion later.
2. a) Large cavity opening
Slide the appliance into the cavity.
b) Smaller cavity opening
Release the two screws retaining the vent slider to the
front of the
fi
rebox.
Remove the slider from the
fi
rebox by sliding it towards
the back of the
fi
rebox.
3. Apply RTV sealant to the collars on the vent slider and
fi
t the
two liners
ensuring that the exhaust liner is connected to
the identifi ed “EXHAUST” vent collar
. Secure with 4 tapping
screws per liner.
If the vent slider was removed from the
fi
rebox, slide the
fi
rebox
onto the vent slider in the cavity taking care not to damage the
liners.
Make sure that the rear edge of the slider is hooked over
the cleat on the fi rebox.
Secure the vent slider to the front of the
fi
rebox with two screws removed earlier.
4. From the roof, pull
the liners and
fi
t the
fl
ashing.
5. Fit the terminal
cap
ensuring that
the exhaust liner
is connected to
the exhaust vent
collar
. Secure with
8 screws provided.
6. Seal the terminal
and
fl
ashing from
water penetration
as required.
1
3
4
5
Appliance Preparation
option 2b
option 2a
6
Vent slider
cleat
WARNING
Failure to position the parts in
Failure to position the parts in
accordance with these diagrams or
accordance with these diagrams or
failure to use only parts speci
fi
cally
failure to use only parts speci
fi
cally
approved with this appliance
approved with this appliance
may result in property damage or
may result in property damage or
personal injury.
personal injury.
WARNING
!
23
QUALIFIED
INSTALLER