1
Note:
This kit must be installed or serviced by a qualified installer, service agency or gas supplier.
These instructions are to be used in conjunction with the main installation instructions for the above
listed models.
WARNING: If these instructions are not followed exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
GROUNDING:
This power supply must be installed and grounded in accordance with local codes,
or in the absence of local codes, with the current
Canadian Electrical Code
CSA C22.1. or in the
USA the
National Electrical Code
ANSI/NFPA70 latest edition.
Description of System
The models listed above have been designed to
accommodate the installation of a 150CFM air
circulation fan.
Operated via the remote control handset and having
variable speed control, the fan is designed to boost the
natural convection through the heater; this may be a
desirable feature dependent on the fireplace location
and room layout.
It is preferable to install the circulating fan before
the heater is installed
although it may also be
retrofitted at a later date provided power is available
at the fan location. However, please note that the
retrofitting of the fan is done by disconnecting the
gas and removing the heater form the cavity. Once
installed, the fan may be serviced from inside the
firebox without removing the heater from the cavity
(780 only).
The fan is designed for automatic operation to come
on and off when the burner comes on and off. The
fan speed can be controlled from the remote control
handset. There are four speeds available. The fan
will start approximately 4 minutes after lighting the
appliance and will continue to run for approximately 10
minutes after the burner is shut off. The fan will go on
and off at the speed last selected by the user.
795CFK CIRCULATING FAN KIT
INSTALLATION and OPERATING INSTRUCTIONS
CSA approved for use only with
Valor models 780 and 785
4002487-02
© 2010, Miles Industries Ltd. All rights reserved.
G4 S
erieS
Operation
To operate the fan, press the “SET” button on the
remote handset until only the fan icon ( ) appears
on the display and is flashing. Press the up/down
buttons to set the fan speed ( ). No bars showing
means the fan is OFF. Once the flashing stops, the fan
is set. The fan icon and number of bars will show when
the remote is in other modes to confirm the fan status.
Note: The fan, when plugged in, provides power for
the remote control receiver via the fan control module.
Therefore batteries are no longer required in the
receiver other than for back-up purposes. A battery is
still required in the remote control handset.
Electrical Requirements
The fan kit requires a power supply of
120 Volts,
1 phase, 60 Hz. Full load current is less than 1 amp
.