background image

4

Access for servicing—780 fireplace

Before carrying out any maintenance, make sure the 

fireplace is turned off including the pilot.

MAKE SURE THE FIREPLACE IS COLD!

1. 

Access the fan.

a)  Remove the front, trim, and other accessory 

necessary to have access to the gas valve 

on the left hand side of the appliance and the 

window. See the instruction manual supplied 

with the 780 appliance.

b)  Below the gas valve, turn the switch off (O) so 

the fireplace does not start accidentally.

c)  Remove the window, the ceramic rocks or logs, 

and the grate (logs only).

d)  Remove the rear log support (3 screws).

Remove for maintenance—780

Window, logs, rocks, 

ceramic walls

Rear log support

Front brick support

Air baffle

Fan access panel

WARNING

DO NOT TOUCH THE FIREPLACE WHILE IT IS 

HOT! 

Let it cool first before any maintenance.

e)  Remove the front log support.

f)  Remove the ceramic walls.
g)  Remove the air baffle on the rear wall (6 

screws).

h)  Remove the fan access panel on the rear wall 

(12 screws).

Summary of Contents for Legend G4 Series

Page 1: ...cavity Once installed the fan may be serviced from inside the firebox without removing the heater from the cavity 780 only The fan is designed for automatic operation to come on and off when the burne...

Page 2: ...an mounting hole and apply the self adhesive wiring diagram label provided to the rear side of the fan access panel as shown 6 foot electrical cord Fan control wire module to receiver Wiring diagram F...

Page 3: ...perated with the remote control system It has 4 speed levels On the remote control handset s display this icon represent the fan and this icon represents the speed One bar is low four bars is high 1 A...

Page 4: ...b Below the gas valve turn the switch off O so the fireplace does not start accidentally c Remove the window the ceramic rocks or logs and the grate logs only d Remove the rear log support 3 screws Re...

Page 5: ...to remove the fan control module remove the fan first The module is on the left hand side of the fan and it is held in place by a piece of Velcro a Pull the fan out of the enclosure as indicated in st...

Page 6: ...the fireplace 2 screws and slide it out of the firebox d Pull the appliance out of the cavity You need access to the left hand side and the rear of the appliance 2 Remove the left side valve access pa...

Page 7: ...within the enclosure to avoid any vibration when functioning 2 Removing the fan control module The module is held in place by a piece of Velcro Disconnect the power the fan and the receiver connector...

Page 8: ...ve the grounded prong from this plug Designed and Manufactured by for Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver B C CANADA V7H 3B1 Tel 604 984 3496 Fax 604 984 0246 www valorfire...

Page 9: ...r s lectionnez la vitesse d abord Sur la manette de la t l commande appuyez sur le bouton SET plusieurs fois jusqu ce que l ic ne du ventilateur apparaisse et clignote Appuyez sur les deux boutons des...

Page 10: ...le ventilateur collez l tiquette du sch ma des connexions sur le panneau d acc s au ventilateur tel qu indiqu Note le panneau d acc s au ventilateur est accessible de l int rieur de la bo te de foyer...

Page 11: ...ignotera 3 Appuyez sur le bouton de la grande flamme pour activer le ventilateur et augmenter sa vitesse 4 Appuyez sur le bouton de la petite flamme pour r duire la vitesse du ventilateur ou pour l te...

Page 12: ...llume pas accidentellement c Enlevez la fen tre les b ches ou pierres de c ramique et le porte b ches version b ches seulement Enlevez pour l entretien 780 Fen tre b ches pierres panneaux Support de b...

Page 13: ...ntilateur enlevez d abord le ventilateur Le module est situ gauche du ventilateur et il est maintenu en place par une pi ce de Velcro a Sortez le ventilateur hors de son bo tier tel qu indiqu l tape 2...

Page 14: ...pareil d Tirez l appareil hors de sa cavit Vous devez avoir acc s au c t gauche de l appareil et l arri re 2 Enlevez le panneau d acc s la soupape sur le c t gauche 5 vis 3 D branchez le ventilateur d...

Page 15: ...pi ce de Velcro D branchez les bornes du cordon d alimentation POWER du ventilateur FAN et le fil du module au r cepteur Notez D branchez les bornes pince NE TIREZ PAS SUR LES FILS 3 Rebranchez et r i...

Page 16: ...URER VIS DE MISE LA TERRE CORDON LECTRIQUE DE 6 PIEDS 1 9 M MIS LA TERRE BO TIER DU VENTILATEUR VENTILATEUR MODULE DE COMMANDE VENTILATEUR R CEPTEUR DE T L COMMANDE FOURNI AVEC LE FOYER NOTE LE FILAGE...

Reviews: