 First time operation

When operating your new 

fi

 replace for the 

fi

 rst time, 

some  vapors may be released due to the burning of 

curing compounds used during manufacturing. They 

may cause a slight  odor and could cause the 

fl

 ames 

to be the full height of the 

fi

 rebox, or even slightly 

higher, for the 

fi

 rst few hours of operation.

It is also possible that these vapors could set o

  any 

smoke detection alarms in the immediate vicinity. 

These vapors are quite normal on new 

fi

 replaces. 

We recommend opening a window to vent the 

room. After a few hours of use, the vapors will have 

disappeared and the 

fl

 ames will be at their normal 

height.

Valor automatic gas shut-o

 

For your safety, Valor 

fi

 replaces are 

fi

 tted with a 

fl

 ame supervision device which will shut-o

  the  gas 

supply if, for any reason, the pilot 

fl

 ame goes out. 

This device incorporates a 

fi

 xed probe, which senses 

the heat from the pilot 

fl

 ame. If the probe is cool, 

the device will prevent any gas 

fl

 ow unless manually 

lighting the pilot. See the full Fireplace and Lighting 

Information card attached to the 

fi

 replace or as 

reproduced in Appendix A of the Installation Manual.

 Locating 

fi

 replace and lighting information

The Fireplace and Lighting Information card is located 

on a card under the 

fi

 rebox, below the end window, 

on end opposite the wall.
To access the card, remove the front and end barrier 

screens, and front sill (all held in place by magnets). 

See diagrams at right.
 The card is located at the end of the unit. There is 

important information on both sides of the card. It 

must be left with the 

fi

 replace when you are done.

Getting started

WARNING

Do not attempt to access the card while 

the 

fi

 replace is hot! Let the 

fi

 replace cool 

fi

 rst before touching it!

739MN

FOR NATURAL GAS    POUR LE GAZ NATUREL

750

24,000

6,500

3.2"

5.0"

4006176N/01

CIRCULATING FAN KIT 755CFK     VENTILATEUR POUR CIRCULATION D'AIR 755CFK

#4003360-741, #4003293-742, #4003313-745, #4003426-765, #4004666 772

   120V, 60Hz, LESS THAN 1A

   120V, 60Hz, MOINS DE 1A

739N 10000

Fireplace 

model
Serial 

number

 Locating info card

Info 

card

LX1 pier

LX2 3-sided

LX2 corner L+R

Summary of Contents for LX Series

Page 1: ...a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service age...

Page 2: ...rohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used INS...

Page 3: ...__________________________________________ Options ________________________________________ ________________________________________________ ________________________________________________ Please ask...

Page 4: ...f the fireplace can get very hot when the fireplace heats Although safe they may reach temperatures in excess of 200 F depending on elevation of the shelf Do not place anything on it Some materials or...

Page 5: ...chnician to inspect the appliance and to replace any part of the control system and any gas control that has been under water Intended use This appliance is designed and approved as a supplemental hea...

Page 6: ...rvised when they are in the same room as the appliance Toddlers young children and others may be sus ceptible to accidental contact burns A physical barrier is recommended if there are at risk individ...

Page 7: ...any gas flow unless manually lighting the pilot See the full Fireplace and Lighting Information card attached to the fireplace or as reproduced in Appendix A of the Installation Manual Locating firep...

Page 8: ...onents of your installed fireplace with the protective barriers installed Your individual fireplace may appear differently depending on your installed options Here are the control components of your i...

Page 9: ...r fireplace OFF including pilot Press and hold button on remote or ON OFF button on wall switch If the flames or pilot are on they will go out and you will hear the valve motor wind down You will hear...

Page 10: ...urn child proofing OFF 1 Press and hold the and buttons simultaneously 2 disappears from the handset screen and the handset is returned to full functionality Preventing inadvertent ignition You can us...

Page 11: ...n the remote wall switch no tools required and withdraw the battery holder straight out from the wall it is attached to the plate Replacing batteries WARNING Do not attempt to access the batteries whi...

Page 12: ...ot to scratch the glass when cleaning See Cleaning your fireplace on page 13 Inspect the operation of the flame safety sys tem Pilot or Flame rectification device Inspect and ensure the lighting of th...

Page 13: ...cate the window retainer hooks Retainer hook locations 2 per side 4 Hook the window handle to one of the spring loaded window levers 5 Pull the window retainer hooks out and up from the railing at the...

Page 14: ...e bottle container Our dealers have experienced good results from the products listed below We cannot however guaran tee results of these products Brasso Polish Plus by KelKem Cook Top Clean Creme by...

Page 15: ...st the end window Out Bottom railing Log position Log position is important in your Valor fireplace because it can optimize the beauty of the flame and the combustion e ciency of your fireplace If log...

Page 16: ...performance of the fireplace Damage components Cause overheating resulting in dangerous conditions Damage caused by incorrect window installation is not covered by the Valor Warranty WARNING For safet...

Page 17: ...other flammable vapors and liquids Inspect the vent terminal outdoors regularly to ensure that it is not obstructed by snow trees bushes leaves or other objects We recommend at least an annual inspect...

Page 18: ...t Light Pilot Light Rock Shale kit Pilot Light Note The height and color of your flames can depend upon many variables including fuel type fuel quality fuel mixture altitude and aeration adjustment at...

Page 19: ...s in your remote control handset but the batteries in the battery holder beside the wall switch See page 11 for instructions on how to replace the batteries Why do I hear popping or snapping noises As...

Page 20: ...our fireplace serviced before initial use and at least once every year by a qualified service technician Contact our dealer quoting the model and serial numbers if possible These numbers can be found...

Page 21: ...form to all applicable codes including national and local gas appliance installation codes and building and re codes d The owner must comply with all operating instructions e The Company is not respon...

Page 22: ...t Fan if included Program Mode Temperature Time Auxiliary Feature not used Countdown Timer Battery Status Eco F or C 7R 7XUQ 2Q LUH 2QH XWWRQ OLJKWLQJ GHIDXOW 7ZR XWWRQ OLJKWLQJ simultaneously 3UHVV D...

Page 23: ...LQJ DQ 2SHUDWLRQ RXQWGRZQ 7LPHU AM AM 7R GHDFWLYDWH IXQFWLRQV QVWDOO EDWWHULHV OO LFRQV DUH GLVSOD HG DQG DVKLQJ KLOH WKH LFRQV DUH DVKLQJ SUHVV WKH UHOHYDQW IXQF WLRQ EXWWRQ DQG KROG IRU VHFRQGV 7KH...

Page 24: ...PRVWDWLF DQG FR PRGHV 0D LPXP FRXQWGRZQ WLPH LV KRXUV DQG PLQXWHV LJKW LPPHU 2SHUDWLRQ On Press LV GLVSOD HG LJKW LV RQ DW SUHVHW OHYHO 2II Press GLVDSSHDUV LJKW WXUQV R Setting Press and hold until D...

Page 25: ...will display 33 0DQXDO 0RGH 7KH RQ R VWDWXV RI WKH UHSODFH DV ZHOO DV DPH KHLJKW DUH PDQXDOO FRQWUROOHG E WKH XVHU PM ON OFF PM PM 7KHUPRVWDWLF 0RGH On Press LV GLVSOD HG 3UHVHW WHPSHUDWXUH GLVSOD V E...

Page 26: ...H 6HWWLQJ 352 5 0 1 OFF DUH GLVSOD HG ALL is GLVSOD HG EULH RXU DVKHV To select hour press or 7R FRQ UP SUHVV 1 OFF DUH GLVSOD HG ALL GLVSOD HG EULH 0LQXWHV DVK To select minutes press or 7R FRQ UP SU...

Page 27: ...XWHV CAUTION R QRW XVH D VFUHZGULYHU RU RWKHU metallic object to remove the batteries from the EDWWHU KROGHU RU WKH KDQGVHW 7KLV FRXOG FDXVH D VKRUW FLUFXLW RZ DWWHU 5HFHLYHU With low battery power in...

Page 28: ...SSO OLQH 1R VSDUN Reversed polarity in thermocouple wiring QFRUUHFW SLORW RUL FH LI YDOYH KDV EHHQ FRQYHUWHG IURP 3 WR 1 RU YLFH YHUVD F09 F09 4 sec Fire is not responding 1R HOHFWURQLF FRQWURO RI UH...