Appliance Preparation
Venting Outlet
If the appliance is to be vented from the
top
, it is ready
for vent installation once the engine is on the casting
base.
If the appliance is to be vented from the
rear
, it must be
converted. Follow these simple steps:
1. Remove the following parts in this order:
a) Dura-Vent collar, gasket and intake plate from
the top of the appliance (22 screws of the intake
plate and 2 rear screws of the collar);
b) Exhaust collar (8 screws).
NOTE: The gaskets are glued to the engine or
the intake plate; it is not necessary to separate
them from the parts they are attached to.
However, if they need to be manipulated,
BE
CAREFUL not to damage them because their
material is fragile.
2. Re-install through the vent opening at the rear of the
fi
rebox in the reverse order in which you took the
parts out.
Co-linear Applications
For conversion of top or rear outlet collars to co-linear
(two 3-inch pipes) rear venting, refer to instructions
packaged with the 556CLA Co-linear Adapter.
NOTE:
Co-linear venting may only be installed into
solid-fuel burning
fi
replaces and chimneys.
Top Spar
1. Position the top spar on the side brackets located
between the engine and the cast sides.
2. Fix the spar with four 3/8” pre-assembled screws
provided.
INSTALLATION