OWNER’S
INFORMATION
7
Owner’s Information
b. While holding the screen, swivel down the top
levers and push them away from the center to
lock the screen. Check that the screen is solidly
hooked to the window frame.
Checks
A
periodic check of the pilot and burner
ames should
be made. Check after the
re has been on for at least
30 minutes. The pilot
ame must cover the tip of the
thermocouple probe. The main burner
ame pattern will
vary from appliance to appliance depending on the type of
installation and climatic conditions—see images below.
The appliance area must always be kept clear and
free from combustible materials, gasoline and other
ammable vapors and liquids. Inspect the vent terminal
outdoors regularly to make sure that, snow, leaves,
bushes, trees, etc, do not obstruct it. Examine the vent
system and terminal regularly. We recommend annually.
7. Reinstall the window.
a. Hook the window over
the top edge of the
rebox, and fasten
the bottom two
spring- loaded
bolts by pushing
in and turning
them 90
degrees.
b.
If the Hot Glass Warning plate has been
removed from the front lower corner of the
window, reinstall it by sliding it between the
glass and the frame as indicated.
8.
Reinstall the barrier screen.
a. Hook the bottom of the screen to the bottom
edge of the window frame and then push the
screen against the window frame.
Pilot Flame
Thermocouple
Probe must be
in Flame
Correct Flame Picture
Spring-loaded
Fastening Studs (2)
1/4 Turn
Hot Glass Plate
WARNING
FOR SAFETY PURPOSE, ensure the barrier
FOR SAFETY PURPOSE, ensure the barrier
screen is re-installed on the
replace window
screen is re-installed on the
replace window
after maintenance.
after maintenance.
WARNING
!
Top view—Hook bottom of screen to bottom of
window frame
Convection baf
e
Summary of Contents for Retrofire RF24XBN
Page 30: ......