background image

Willow Multifuel Stoves

19

SPARE PARTS

AFS1086

AFS1087

AFS008

AFS1088

AFS009A

2.

Throat Plate

3.

Fuel Grate

5.

Operating Tool

7.

Ashpan

4.

Flue Spigot

Part Description

Visual Aid

(not to scale)

Willow 

Part No.

6. 

Fire Door

Locking Assembly

AFS204

1. 

Main Door

Assembly Complete
with Handle,Glass,
Gaskets,Clips and
Seal.

AFS1098

Summary of Contents for Willow

Page 1: ...e Erdington Willow Multifuel Stove Operating Installation Manual PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Willow Multifuel Stove Rev 1 Summer 2003 Part No AFS1128 Tel 49 0 40 8890100 www...

Page 2: ...LEUM COKE SOME OF WHOSE BRAND NAMES ARE CALCO PETROCOKE OR WONDERCO MUST NOT BE BURNED IN THIS APPLIANCE TO USE THESE FUELS WILL INVALIDATE THE APPLIANCE GUARANTEE IF IN DOUBT CONTACT THE SOLID FUEL A...

Page 3: ...g the Optional Floor Fixing Kit 8 Fitting the Flue Outlet and Hotplate 9 Flues Chimneys 9 12 Page OPERATING INSTRUCTIONS Air Inlet Controls 13 Multi Purpose Operating Tool 13 Fire Door Glass 14 Adjust...

Page 4: ...modern equipment available It is a highly efficient and sophisticated piece of machinery and when properly installed and operated it should provide a lifetime of heating satisfaction Safety is the mo...

Page 5: ...t 1 4 AFS009A 6 Ash pan 1 AFS1088 7 Operating tool 1 AFS008 8 Rear liners 1 AFS1093 9 Side liners 2 AFS1091 The model and Serial Number of your fire can be found stamped into the casing centrally just...

Page 6: ...m Min Max Room heater only output kW 1 4 kW TECHNICAL DATA Willow Multifuel Height mm 455 Width mm 350 Depth mm 345 Height to centre of rear flue N A Depth from back to centre of flue 90 Flue diameter...

Page 7: ...e fire should be installed to stand on a constructional hearth of non combustible materials not less than 125mm 5 thick conforming to Building Regulations Dimensions of the hearth should project at le...

Page 8: ...w Fig 2 Inserting throat plate Fig 3 Liners throat plate and grate in the Willow REMOVAL OF THE THROAT PLATE Blocked chimneys cause dangerous fumes to escape Remove throat plate at least monthly to cl...

Page 9: ...mply with the Building Regulations The minimum effective height of the flue must be at least 4 5 metres from the top of the stove to the top of the flue outlet When warm the flue draught should be bet...

Page 10: ...pect of providing a Notice Plate giving details on the chimney flue lining hearth and fireplace installation Approved Document J of the Building Regulations for England and Wales is available from The...

Page 11: ...Willow Multifuel Stove 11 INSTALLATION...

Page 12: ...12 Willow Multifuel Stove INSTALLATION TYPICAL METAL INSULATED CHIMNEY SYSTEM TO BE INSTALLED TO THE CHIMNEY MANUFACTURERS INSTRUCTIONS IN COMPLIANCE WITH BUILDING REGULATIONS AND BS7566 PTS 1 4...

Page 13: ...TEM The air wash has an internal sliding plate with slots housed in a cover plate and is located above the fire door Sliding the control knob to the right as far as it will go achieves the fully open...

Page 14: ...s shown below fig 12a Fig 12a fitting new door gasket Re seat the new glass ensuring the sealing gasket is flat and in contact with the glass Fig 12b fitting new glass Replace the two lower retaining...

Page 15: ...himney your wood is Green or too wet Recommended Reading Wood as Fuel available from the Forestry Commission Peat Can be used in turf or briquette form but again the moisture content must be low Paper...

Page 16: ...sure that the multifuel grate and ash pan are in position and the fire doors are closed Set the air wash to one quarter open position Set the primary inlet to the fully open position Light in the norm...

Page 17: ...corrected ASH REMOVAL The appliance will require ash to be removed periodically but an ash bed of approximately 20mm 3 4 should be maintained Ash may be removed with a small shovel whilst the fire is...

Page 18: ...east twice per burning season It is important that the flue ways flue pipe and chimney be cleaned prior to lighting the fire after a prolonged shut down period DOOR GLASS The door glass should remain...

Page 19: ...008 AFS1088 AFS009A 2 Throat Plate 3 Fuel Grate 5 Operating Tool 7 Ashpan 4 Flue Spigot Part Description Visual Aid not to scale Willow Part No 6 Fire Door Locking Assembly AFS204 1 Main Door Assembly...

Page 20: ...iner 10 Back Liner Set 11 Glass Replacement Kit Complete with Gasket 12 Glass Clips with Gasket 13 Hinge kit Comprises 2 Hinges 4 Fixings Per Set 14 Willow Airwash Part Description Visual Aid not to s...

Page 21: ...uarantee periods commence on the date of purchase and are non transferable Our Guarantee is offered as an addition to your statutory rights Guarantee applicable to original purchaser only Not transfer...

Page 22: ...PARTS FLUE OUTLET GRATE FIREBOX LININGS THROAT PLATE AIR WASH DOOR CATCHES ASH PAN OPERATING TOOL OPERATING INSTRUCTIONS Model Serial No I ve checked it and it s O K Assembled by Checked by Baxi Fire...

Reviews: