DSBA3400 • Rév. 09/06/2020
49
EN
VS technical specifications
1)
L’actionneur accepte les fluctuations de la tension du RÉSEAU d'alimentation jusqu'à ±10 % de la tension nominale.
2)
Accepte les surtensions temporaires survenant sur le réseau d’alimentation.
VS100 VS150
VS300
Installation
IP protection (EN60529)
IP68 (5 m 72 h)
Corrosion resistance (outdoor and
indoor use)
Housing: Alu EPOXY paint / cover: PA6 UL 94 V-0 or Alu EPOXY
paint
Drive : Steel + Zn treatment / Axles and screws : Stainless steel
Temperature
-20 °C à +70 °C (BBPR/GPS/GFS : -10 °C à +40 °C)
Hygrometry
maximum relative humidity 80 % for temperatures up to 31 °C decreasing linearly
to 50 % relative humidity at 40 °C
Pollution degree
Applicable POLLUTION DEGREE of the intended environment is 2 (in most cases).
Altitude
altitude up to 2 000 m
Extended environmental conditions
Outdoor use and in WET LOCATION
Sound level
61 dB
Weight
5,1 kg to 5.5 Kg max (6 Kg to 6,4 kg with aluminium cover)
Mechanical specifications
Nominal torque
75Nm
125Nm
250Nm
Maximum torque
100Nm
150Nm
300Nm
Operating time (90°)
15 s (400 V : 10 s)
30 s (400 V : 20 s)
60 s (400 V : 35 s)
Drive ISO5211
Star 22 F07-F10
Rotation angle
90° (others on request)
Mechanical stops
90°
Manual override
Wheel
Direction of rotation
Anticlockwise to open
Electrical specifications
Voltage
1)
(standard)
100 V to 240 V AC 50/60 Hz and 100 V to 350 V DC
15 V to 30 V AC 50/60 Hz and 12 V to 48 V DC
3-phase 400 V 50/60 Hz
Overvoltage category
2)
TRANSIENT OVERVOLTAGES up to the levels of OVERVOLTAGE CATEGORY ll
TEMPORARY OVERVOLTAGES occurring on the MAINS supply.
Power consumption
45 W - (135 W for 400 V)
Insulation motor class
Class B 400V motors and class F for the others
Torque limiter
Electronical
Duty cycle (CEI34)
50%
Limit switches maximal voltage
4 to 250 V AC/DC
(Overvoltage category II)
Limit switches maximal current
1 mA to 5 A max
Anticondensation heaters
10 W
Inrush current
Circuit breaker type D, nominal current according the number of actuators (max. 4 actu-
ators) or use a inrush current limiter at the output of the circuit breaker.
Voltage
1)
(GP5 and GF3)
100 V to 240 V AC 50/60 Hz and 100 V to 350 V DC
15 V to 30 V AC 50/60 Hz and 12 V to 48 V DC
Voltage
1)
(GP6, GPS and GFS)
100 V to 240 V AC 50/60 Hz and 100 V to 350 V DC
24 V to 30 V AC 50/60 Hz and 24 V to 48 V DC