qUICK STARTING TIPS FOR UNITS THAT 

HAvE BEEN SITTING FOR A WHILE

If your unit has not been used for a long period of time 
and it is hard to start it, try to do some of these easy 
steps before calling the customers hotline.
Check the oil level.
Replace the old fuel.
Change the spark plug.
Check the fuel lines. Make sure the fuel valve is open.
Check all generator parts for integrity
Clean  the  carburetor.  (See  engine  manual  for  service 
centers)

1
2

3

4
5
6

Before each use, review the general conditions for the 
generator, review that all the pieces are complete, review 
if there are damaged cables or some other condition that 
can affect that the generator operates on safe way. If a 
strange noise is listened to or some abnormal vibration, 
turn  off  the  generator  immediately.  Be  sure  to  fix  the 
problem before giving the generator more use. Do not 
use the equipment damaged.
Periodically  inspect  all  the  screws  and  bolts  to  check 
they are in place and tight.
Keep this equipment in a clean and dry place.
For the best maintenance of the engine and any other 
problem, read the engine owner’s manual.
After the engine has become cool, remove the excessive 
gasoline and store it in a container, safe and approved 
for that purpose.
After the first 20 hours of use of the generator drain and 
replace the oil of the engine, after that the oil must be 
changed every 100 working hours

HEAT SHIELD:

Inspect to ensure that all heat shields and heat deflectors 
are intact and in place. Removing of these parts could 
cause serious damage to the unit.

ENGINE: Carburetor Icing

During the winter months, rare atmospheric conditions 
could  cause  an  icing  condition  in  the  carburetor.  If  it 
happens, the engine may run rough, loose power, and 
may stall. Call Product Service for more information.

NOTE: 

Refer to the engine manufacturer’s manual for 

service and maintenance of the engine.

SERvICE AND STORAGE

INFREqUENT SERvICE

If the unit is used infrequently, difficult starting may result, 
to eliminate hard starting, run the generator at least 30 
minutes every 15 days. Also, if the unit will not be used 
for some time, it is a good idea to drain the fuel from the 
carburetor and gas tank.

LONG TERM STORAGE

When the generator set is not being operated or is being 
stored more than one month, follow these instructions:
Replenish engine oil to upper level.
Drain gasoline from fuel tank line and carburetor.
Pour about one teaspoon of engine oil through the spark 
plug hole, pull the recoil starter several times and replace 
the plug. Then pull the starter until you feel piston is on 
its compression stroke and leave it in that position. This 
closes both the intake and exhaust valves to prevent the 
inside of cylinder from rusting.
Cover the unit and store in a clean, dry place that is well 
ventilated away from open flame or sparks.
NOTE:  We  recommend  always  using  a  fuel  stabilizer. 
A fuel stabilizer will minimize the formation of fuel gum 
deposits during storage. The fuel stabilizer can be added 
to the gasoline in the fuel tank, or into the gasoline in a 
storage container.

1
2
3

4

THE MANUFACTURER AND/OR DISTRIBUTOR HAS 
PROVIDED THE PARTS DIAGRAM IN THIS MANUAL 
AS  A  REFERENCE  TOOL  ONLY.  NEITHER  THE 
MANUFACTURER NOR DISTRIBUTOR MAKES ANY 
REPRESENTATION OR WARRANTY OF ANY KIND 

TO THE BUYER THAT HE OR SHE IS QUALIFIED TO 

MAKE ANY REPAIRS TO THE PRODUCT OR THAT 

HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS 

OF THE PRODUCT. IN FACT, THE MANUFACTURER 
AND/OR  DISTRIBUTOR  EXPRESSLY  STATES 
THAT ALL REPAIRS AND PARTS REPLACEMENTS 
SHOULD  BE  UNDERTAKEN  BY  CERTIFIED  AND 
LICENSED TECHNICIANS AND NOT BY THE BUYER. 
THE  BUYER ASSUMES ALL  RISK AND  LIABILITY 
ARISING  OUT  OF  HIS  OR  HER  REPAIRS TO THE 
ORIGINAL  PRODUCT  OR  REPLACEMENT  PARTS 
THERETO,  OR  ARISING  OUT  OF  HIS  OR  HER 
INSTALLATION OF REPLACEMENT PARTS THERE 
TO.

READ THE FOLLOWING CAREFULLY

Summary of Contents for G120MG2200RV

Page 1: ......

Page 2: ...tive locations such as metal decking and steel work SAFETY INFORMATION DANGER indicates a potentially hazardous situation which if not avoided WILL result in death or serious injury WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION indicates a potentially hazardous situation which if not avoided may result in minor or moderate ...

Page 3: ...BA is a hazard to hearing Always wear ear protection when operating or working around the generator when it is running The generator should be operated serviced and refueled under the follow Conditions a Start and run the generator outdoors Do not run the generator in an enclosed area even if doors or windows are open avoid areas where vapors may be trapped such as pits garages cellars excavations...

Page 4: ...ectrical codes Proper use requires that a double throw transfer switch be installed by licensed qualified electrician so that the building s electrical circuits may be safely switched between utility power and the generator output thereby preventing back feed into the power utility s electrical system Always follow local codes and regulations that apply to the installation of any item that concern...

Page 5: ...l sum the amperes marked in the nameplates of each tool to determine the minimum cord gauge you need to use The extensions for 120 volts are made of 3 cables where the green cable is the grounding one the white cable is the neutral and the black cable is the hot wire 1 2 3 4 5 6 7 CAUTION Do not overfill the tank Keep maximum fuel level to inch below the top of the tank This will allow for expansi...

Page 6: ...less colorless poison gas Breathingcarbonmonoxidecancausenausea fainting or death 1 2 3 4 5 6 7 All engines exhaust carbon monoxide a deadly gas Breathing carbon monoxide can cause headaches dizziness nausea confusion and eventually death The carbon monoxide is colorless odorless tasteless gas which may be present even if you do not see or smell any engine exhaust Deadly levels of carbon monoxide ...

Page 7: ...cool 1 2 3 4 5 6 Controlled initial start helps insurance of proper engine and generator operation Follow engine start procedure outlined in engine manual Before starting your generator you must install the following components Handles wheel kit and battery holder battery is not included handle installation 1 2 3 4 6 5 Unpack and inspect all parts to see if there are not missing or defective parts...

Page 8: ... Secure the battery using the brackets attach on the battery holder Identify the red and black wires with positive and negative electrodes of the battery Connect the red wire to the positive terminal of the battery and the black wire to the negative terminal See Fig Handle the battery carefully as it contains highly corrosive acid and can cause burns Never connect the red wire to black this can ca...

Page 9: ...Refer to the engine manufacturer s manual for service and maintenance of the engine service and storage INFREQUENT SERVICE If the unit is used infrequently difficult starting may result to eliminate hard starting run the generator at least 30 minutes every 15 days Also if the unit will not be used for some time it is a good idea to drain the fuel from the carburetor and gas tank LONG TERM STORAGE ...

Page 10: ...SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 10 WIRING DIAGRAM ...

Page 11: ...SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 11 IDLE DOWN WIRING DIAGRAM ...

Page 12: ...SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 12 G120 G135 SPARE PARTS LIST ...

Page 13: ... potencialmente peligrosa que si no se evita PROVOCARÁ muerte o una lesión seria ADVERTENCIA indica una situación de peligro potencial la cual si no se evita podría ocasionar lesiones severas e incluso la muerte PRECAUCION indica una situación potencialmente de riesgo la cual si no se evita puede ocasionar heridas personales menores o moderadas o daños materiales PELIGRO ADVERTENCIA PRECAUCION Nun...

Page 14: ...ra del Generador No use ropa demasiado holgada alhajas o cualquier otra cosa que se pueda atrapar en el alternador u otras partes movibles La unidad debe de alcanzar la velocidad de operación antes de conectarse las cargas eléctricas Desconecte as cargas antes de apagar el motor Para evitar sobrecargas que podrían dañar el equipo no permita que el motor se quede sin combustible al aplicarse las ca...

Page 15: ...dor va usarse como fuente de energía de reserva en caso de un fallo del suministro eléctrico debe de ser instalado por un electricista calificado de acuerdo con todos los códigos eléctricos locales aplicables El uso apropiado requiere la instalación de un interruptor de transferencia de doble tiro por un electricista capacitado y calificado para asegurar que los circuitos eléctricos del edificio p...

Page 16: ... se obtenga un valor alto de octanaje por lo menos 85 octanos Recomendamos que siempre utilice un aditivo de gasolina Un aditivo de gasolina minimizará la formación de depósitos de goma de gasolina durante el almacenamiento El aditivo de gasolina puede agregarse a la gasolina en el tanque de combustible o junto con la gasolina en un contenedor de almacenamiento El combustible y el humo del motor s...

Page 17: ...enerador Calcule la potencia total de los equipos La potencia máxima del generador está indicada en la hoja de especificaciones 1 2 3 4 conexiones del generador Si el generador va a ser utilizado para sustituir energía en épocas de interrupciones la entrada de energía debe ser aislada Refiérase a las medidas de seguridad eléctricas del generador en la sección INSTALACION Estas conexiones se deben ...

Page 18: ...ica fuerte durante el periodo inicial de funcionamiento las primeras 2 ó 3 horas de operación COMO APLICAR UNA CARGA APAGADO DEL GENERADOR ARRANQUE INICIAL 1 2 3 4 5 6 PELIGRO Debe suministrar una ventilación adecuada para los gases tóxicos de escape y el flujo de aire que enfria al motor el motor es enfriado por aire que es inyectado por su propio ventilador No encienda o arranque el generador en...

Page 19: ...taje de las llanta y colque 2 anillos separadores a ambos lados Inserte ambas llantas en el eje y asegúrelas con las chavetas 4 inst de soporte frontal 1 Coloque el extremo del generador sin llantas sobre los bloques de madera permitiendo un espacio para colocar el soporte del generador Fije el soporte frontal a la base con los tornillos suministrados y aprietelos bien como se indica en el dibujo ...

Page 20: ...do Inspeccione periódicamente todas las tuercas y tonillos que se encuentren en su lugar y apretados Guarde su equipo en un lugar limpio y seco Para el mejor mantenimiento del motor y cualquier otro problema acuda al manual de propietario del motor Después de que el motor se haya enfriado remueva la gasolina excedente y almacénela en un recipiente seguro y aprobado para tal fin A las primeras 20 h...

Page 21: ...olina del tanque de combustible la línea de combustible y del carburador Vierta hasta una cucharadita de aceite para motores a través del orificio de la bujía tire del retráctil varias veces y coloque la bujía Luego tire del arrancador hasta que sienta que el pistón está en su carrera de compresión y déjelo en esta posición Esto cierra las válvulas de entrada y escape para evitar que el interior d...

Page 22: ...ESPECIFICACIONES SUJETAS A CAMBIO SIN PREVIO AVISO 22 DIAGRAMA DE CABLEADO ...

Page 23: ...ESPECIFICACIONES SUJETAS A CAMBIO SIN PREVIO AVISO 23 DIAGRAMA DE CONEXION CONTROL DE VELOCIDAD ...

Page 24: ...by Guadalajara Headquarter Phone 52 33 3668 2560 Fax 52 33 3668 2557 e mail export evans com mx www evans com mx www valsi net Call 888 ready 19 888 73239 19 Nationwide Service Centers EXPLOSIVO DE PARTES G120 G135 ...

Reviews: