3.10.2.10 Rear lower links' position view
The view shows the position of the rear lower links
.
1.2 17:52
50
1
GUID-D2673DEE-E150-401F-8439-8E61709A3C22
1. Position of the rear lower links
The display shows the symbol
and the position of the rear lower links on a
percentage scale 0-100:
•
0 = The lower links are in the lowest position.
•
50 = The lower links are in the middle position.
•
100 = The lower links are in the top position.
NOTE: The percentage value may not achieve the limit values (0 or 100) even if
the linkage is functioning correctly.
3.10.2.11 Gearbox temperature view
1.2 17:52
76
1
GUID-DB9A91EC-CD8C-4B22-9996-B695BF76858C
1. Gearbox temperature
The gearbox temperature
is displayed as follows:
•
When the temperature is below +40°C (+104°F), the text "lo" is displayed.
•
When the temperature is b40-+119°C (+104-+246°F), the actual
temperature is displayed.
•
When the temperature is above +119°C (+246°F), the text "high" is
displayed.
NOTE: If the gearbox temperature is continuously above +90°C (+194°F), clean
the radiator and check the oil level.
3. Operation
- 166 -
Summary of Contents for Versu N Series
Page 1: ...OPERATOR SMANUAL NSERIES Versu Ref no 39 893 21 3 08 2015 YOUR WORKING MACHINE...
Page 2: ......
Page 517: ......