background image

Page 20 

 

PERU 

HIGH TECH SERVICE SAC 
Lima, Peru 
511-376-4101 
INDUSTRIAL FACTORY S.A. 
Lima, Peru 
511-336-7773 
METALSPRAY SAC 
Lima

,

 Per

ú

 

RUSSIA 

DS Controls 
Veliky Novgorod, Russia 
+7 (8162) 15-79-28 

SOUTH AFRICA 

Spirax Sarco (Pty) Ltd. 
Gauteng, South Africa 
+27 (11) 230 1300 
511-361-1106 

UNITED KINGDOM 

MCE plc 
Stockton-on-Tees, UK 
+44 (0) 1642 882211 

VENEZUELA 

Puffer Sweiven 

 Venezuela 

Edo. Zulia, Venezuela 
58-261-7573410 / 8445 

BRAZIL 

ValvTechnologies, Inc. 
S

ã

o Paulo

,

 Brasil 

+55-12-3939-4522 

CANADA 

CG Industrial Specialties 
Edmonton, Alberta, Canada 
(780) 462-1014 

CHILE 

Soltex Chile S.A. 
Quilicura-Santiago, Chile 
562 7304700 

CHINA 

Beijing Carve Out Valve Equipment 
Co. 
Hai Dian District, Beijing, China 
8610-51717896 

FRANCE 

SMRI  
Martigues, FRANCE 
+33-04-42-13-00-80 

ITALY 

Argo International Europe Ltd. 
Sesto Florentino, Fl, Italy 
39 055 420 6047 
CON-PRO TOSCANA 
Rosignano Solvay (LI), Italy 
+39 0586 7688.1 

 

 

 

© 2 0 1 0   V a l v T e c h n o l o g i e s ,   I n c .  
I O M _ b a l l   v a l v e _ e n g _ 1 0 0 4 2 2 _ r 1 5  

TEXAS 

*ValvTechnologies, Inc. 
5904 Bingle Road 
Houston, Texas 77092 U.S.A. 
Telephone: (713) 860-0400 
Facsimile: (713) 860-0499 
E-mail: 

sales@valv.com

 

Web: 

www.valv.com

 

Celtex Industries 
White Oak, Texas 
(903) 297-8481 
Puffer Sweiven -- Stafford 
Stafford, Texas 
(281) 240-2000 
Puffer Sweiven 

 La Porte 

La Porte, Texas 
(281) 470-2000 
Puffer Sweiven 

 Port Arthur 

Port Arthur, Texas 
(409) 736-2861 

COLORADO 

Nichols-Given Associates, Inc. 
Englewood, Colorado 
(303) 773-1401 

FLORIDA 

American Valve & Pump 
Lakeland, Florida 
(863) 709-0455 

LOUISIANA 

Carter Chambers 
Baton Rouge, LA  
(225) 926-2236 

MASSACHUSETTS 

Power House Supply 
Newburyport, Massachusetts 
(978) 499-9888 

MINNESOTA 

Swanson Flo-Systems, Co. 
Plymouth, Minnesota 
(763) 383-4700 

NEW JERSEY 

Control Associates, Inc. 
Allendale, New Jersey 
(201) 934-9200 

NORTH CAROLINA 

Specialty Valve & Controls 
Charlotte, North Carolina 
(704) 522-9873 

OHIO 

TRIVACO 
Loveland, Ohio 
(513) 697-9890 

WEST VIRGINIA 

GSB, Inc. 
Hurricane, W. Virginia 
(304) 562-3304 

 
INTERNATIONAL 
AUSTRALIA 

FLOTECH Controls PTY LTD 
Balgowlah, NSW Australia 
612 9949 4888 

Factory Authorized Service Centers

 

*   C o r p o r a t e   o f f i c e   a n d   m a n u f a c t u r i n g   p l a n t  

Summary of Contents for V1 Series

Page 1: ...Page VALVTECHNOLOGIES INC BALL VALVE Installation and Operations Maintenance Manual...

Page 2: ...8 LUBRICATION 8 TORQUE TABLES 8 STEM ROTATION POSITION 9 ACTUATORS 9 IV MAINTENANCE 9 DISASSEMBLY 9 REPAIR REWORK 10 11 BELLVILLE SPRING HEIGHTS 11 12 RE ASSEMBLY 12 13 INSTALLING ACTUATOR 13 PRESSURE...

Page 3: ...l is to describe procedures that will ensure safe and successful installation operation and maintenance of the metal seated ball valve assuming a trouble free service life Difficulties encountered in...

Page 4: ...oad Belleville Spring Upstream Seat Guide Body Seal Hard coated Integral Seat Hard coated Ball High Load Belleville Spring Actuator Mounting Pad Live Loaded Gland Springs Gland Gland Packing Actuator...

Page 5: ...ecial Port ACTUATION Lever Operated LV Cast 150 600 Forged 900 Up LC Cast 900 Up LF Forged 150 600 Bare Stem BS Cast 150 600 Forged 900 Up BC Cast 900 Up BF Forged 150 600 VALVE SIZE Nominal Valve Siz...

Page 6: ...h electric actuators should be cycled to the mid stroke position before cycling under power WARNING VALVES SHOULD NEVER BE USED AS A STRUCTURAL MEMBER ORIENTATION CAUTION Valves must be installed with...

Page 7: ...t insulating or stress relieving technique may damage the valve and void the warranty CAUTION Valve must be OPEN during welding CAUTION Valve insulation is prohibited during stress relieving Only insu...

Page 8: ...9 210 285 1 3 8 35 950 1288 290 393 1 1 2 38 1250 1695 370 502 1 5 8 41 1600 2169 480 651 1 3 4 44 2060 2793 500 678 1 7 8 48 2500 3390 750 1017 2 51 3000 4067 900 1220 3 76 10300 13965 3100 4203 3 1...

Page 9: ...actuators should be inspected every three months and be replenished or replaced if required On actuated and gear operated valves an arrow shows the valve position The stem gland and ball and in some...

Page 10: ...iding excessive force remove the entire actuator assembly 6 Remove body seal or gasket depending upon valve design 7 Remove body gasket if applicable 8 Remove ball after mark ing orientation and prote...

Page 11: ...e Ranges Other Valve Components In general these may be cleaned and returned to service If rework is required consult ValvTechnologies Engineering Department The ball is lapped to the end cap using 3...

Page 12: ...ats are parallel to bore 2 Stem shall be inserted through the stem hole from the body cavity side NOTE Mark on top of stem should be on the left of the valve when looking down on the stem and facing d...

Page 13: ...After tightening the bolts the concentricity should again be checked Any misalignment of the operator to the valve may cause binding in the operator which may cause damage to either the valve or the o...

Page 14: ...4 068 1 727 1 1 2 38 045 1 143 068 1 727 2 1 8 54 048 1 219 071 1 803 3 1 16 78 078 1 981 105 2 667 4 1 16 103 095 2 413 125 3 175 5 1 8 130 120 3 048 145 3 683 6 1 16 154 145 3 683 178 4 521 8 1 16 2...

Page 15: ...ecause of access use alternative method shown to the left Belleville Spring Standoff 19 Measure Belleville Spring height Refer to Table 3 for acceptable height range If height is out of specification...

Page 16: ...m SEAT BALL GAP in mm MINIMUM MAXIMUM 5 8 16 N A 087 2 210 1 1 8 29 N A 075 1 905 1 1 2 38 032 813 046 1 168 2 1 8 150 300 54 N A N A 2 1 8 600 4500 54 040 1 016 056 1 422 3 1 16 78 053 1 346 067 1 70...

Page 17: ...s should re main precisely parallel Failure to do so may result in a faulty seal Torque in a star pattern to 1 3 of torque value listed in Table 1 Then torque in a star pattern to 2 3 of torque value...

Page 18: ...will not rotate or operate 1 Actuator has failed 2 Valve packed with debris 3 Stem key has sheared 4 Ball seat gap incorrect 1 Replace or repair actuator 2 Cycle flush valve to re move debris 3 Deter...

Page 19: ...es below RECOMMENDED SPARE PARTS FOR V1 SERIES BALL VALVES CLASS PART DESCRIPTION QTY SAME TYPE SIZE PERCENT COVERAGE A Gland Packing Gland Load Springs 1 3 70 B Body Gasket Metal Belleville Spring 1...

Page 20: ...5 TEXAS ValvTechnologies Inc 5904 Bingle Road Houston Texas 77092 U S A Telephone 713 860 0400 Facsimile 713 860 0499 E mail sales valv com Web www valv com Celtex Industries White Oak Texas 903 297 8...

Reviews: