V-460/610 Series Operating Instructions Ver.2.04E
38
[ 0
x
]▼▲Dec/Inc Move
VAC GAUGE ー
xx
kPa
HT
xx
O
C
x
.
x
s CT
xx
O
C
(
The mark “
〜
” under the cursor indicates it is blinking.
)
[ 0
x
]▼▲Dec/Inc Move
VAC GAUGE ー
xx
kPa
HT
xx
O
F
x
.
x
s CT
xx
O
F
(
The mark “
〜
” under the cursor indicates it is blinking.
)
[ 0
x
]▼▲Dec/Inc Move
VAC TIME
xx
.
x
sec
HT
xx
O
C
x
.
x
s CT
xx
O
C
(
The mark “
〜
” under the cursor indicates it is blinking.
)
[ 0
x
]▼▲Dec/Inc Move
VAC TIME
xx
.
x
sec
HT
xx
O
F
x
.
x
s CT
xx
O
F
(
The mark “
〜
” under the cursor indicates it is blinking.
)
8-4-11 Vacuum gauge vacuuming mode
8-4-10 Timer vacuuming mode
The cursor will blink at the first digit of
“V
AC
TIME
”.
When the cursor is at this position, adjust
the vacuum time by pressing:
Ɣ 8SEXWWRQ
to increase the value.
Ɣ 'RZQEXWWRQ
to decrease the value.
The value will increase or decrease in 0.1 seconds
increment by pressing the button once. If you hold
the button in, the numeric value will increase or
decrease continuously.
[Setting range: 0.1 ~ 99.9 seconds]
Now the timer vacuuming mode is set properly.
Referring to "
8-4-8 Select the desired vacuuming
mode
", place the cursor to "2 Time" by pressing
the button and press the
button to select
the timer vacuuming mode. The following display
will be shown.
The cursor will blink at the first digit of
“1VG.”
When the cursor is at this position, adjust the
vacuum degree by pressing:
Ɣ 8SEXWWRQ
to increase the value.
Ɣ 'RZQEXWWRQ
to decrease the value.
The value will increase or decrease in -1 kPa
increment by pressing the button once. If you hold
the button in, the numeric value will increase or
decrease continuously.
[Setting range: -1 ~ -100 kPa]
Referring to "
8-4-8 Select the desired vacuuming
mode
”, place the cursor to "3 Gauge" by pressing
the button and press the
button to select the
vacuum gauge vacuuming mode. The following
display will be shown.
Attention
For how to set the seal parameters,
please refer to “8-4-5 Set heating
temperature”, “8-4-6 Set heating time”,
and “8-4-7 Set cooling temperature”.
Attention
For how to set the seal parameters,
please refer to “8-4-5 Set heating
temperature”, “8-4-6 Set heating time”,
and “8-4-7 Set cooling temperature”.
Warning
The button on the control unit allows
you to set the vacuum level from -1 to
-100 kPa, but the actual vacuum level
will depend on the ability of the pump
mounted.
Summary of Contents for V-460 Series
Page 61: ...V 460 610 Series Operating Instructions Ver 2 04E 61 ...
Page 66: ...V 460 610 Series Operating Instructions Ver 2 04E 66 12 Electric diagram 110V ...
Page 67: ...V 460 610 Series Operating Instructions Ver 2 04E 67 220V ...
Page 68: ...V 460 610 Series Operating Instructions Ver 2 04E 68 13 Piping diagram V 460 610 series ...
Page 69: ...V 460 610 Series Operating Instructions Ver 2 04E 69 V 460 610C series ...
Page 75: ...V 460 610 Series Operating Instructions Ver 2 04E 75 ...