© March 2018 Van Essen Instruments. All rights reserved
.
www.vanessen.com
5
Figure 5
Position of LED indicators of the Smart Interface Cable.
The three LED indicators are:
•
Green: OK / receiving data from Diver,
•
Yellow: sending data to Diver and
•
Red: check indicator.
When the Smart Interface Cable is connected to a communication cable with a Diver connected the
green OK indicator will turn on.
As soon as communication is initiated, for example reading settings or data from the Diver, the
yellow LED will start blinking, indicating that data is send to the Diver. In return, the Diver will
respond by sending data back to the Smart Interface Cable and the green LED starts blinking. When
the communication is finished the green LED will remain off for approximately 5 seconds, before
being turned on again.
The red LED indicates when an issue arises. There are two modes:
•
The red LED is continuously on:
o
No communication cable is connected.
o
There is an issue with the communication cable, for example the communication
cable is broken.
•
The red LED is blinking: The Diver could not be detected.
2.5
Reading Atmospheric Pressure
The Smart Interface Cable includes a pressure sensor for measuring the atmospheric pressure. Its
value can be read using Diver-Office 2017.2 or higher. Connect the Smart Interface Cable to the
computer and a communication cable with a Diver. In the main window of Diver-Office click on the
Diver
button and the settings from the Diver will be read. In the
Actual Data
section, the
atmospheric pressure will be listed as shown in Figure 6.