AIR N ARC
®
150 SERIES
SECTION 2: SPECIFICATIONS
090051-OP_r0 (FEB-2014)
PAGE - 11
Vanair Manufacturing, Inc.
vanair.com • 800-526-8817
SECTION 2:
SPECIFICATIONS
TABLE 2A: SPECIFICATIONS
SYSTEM INFORMATION
SPECIFICATION
Rated Welder Output
190A High Frequency DC/CC; 100% Duty Cycle @ 150 Amps
Welding Leads
20 Ft.
AC Generator
4,200 Watts Continuous Duty
AC Generator 120V Power Rating
60 Hz 1 PH, 15 Amp Circuits
AC Generator 240V Power Rating
60 Hz 1 PH, 15 Amp
Engine
14HP, Gasoline
I
Engine Oil Capacity
1.37 Quarts 10W30
Fuel Consumption
1.2 GPH @ 3600 RPM Full Engine Load
Fuel Tank Capacity
1.75 Gallons (7 Quarts)
Fuel Type
87 Octane or Higher Unleaded Gasoline
II
Operating Temperature Limits
-20°F to 110°F
Maximum Operating Angle
15°
Engine Speed
3700 RPM (high speed), 1900 RPM (low speed)
Compressor Type
Reciprocating, single-stage
Air Compressor Capacity
20 CFM @ 100 PSI
Pilot Valve
Factory Setting 95-125 PSI
Compressor Air Filter (x 3 Assemblies)
Pleated Paper, Dry-Type
Oil Type/Capacity
Vanguard™ Reciprocating Oil (ISO 68 or equivalent, non-detergent)
Service: 1 Quarts
III
Air Tank Capacity
30 Gallon Tank or Ten (10) Gallon Tank
Tank Pressure Rating
200 PSI
Safety Relief Valve Setting
150 PSI
Electrical System
12 VDC
Cooling System
Air-cooled
Instrument Gauges
Pressure Gauge
Adjustable Air Pressure Control Settings
Cut-in Pressure: 90 PSI / Cut-out Pressure: 125 PSI (Factory Preset);
150 PSI (Maximum Cut-out)
Generator Receptacles
One (1) 240V Receptacle and One (1) 120V Duplex Receptacle, Both
Located on Generator Panel Face
Air Service Outlet
3/8” NPT Ball Valve
I
For in-depth specifications and requirements regarding the Kohler
®
CH440
engine, refer to the Engine Owner’s
Manual.
II
Ethanol blended fuels, such as E85, are prohibited for use with the Kohler CH440 engine.
DO NOT
use ethanol-
based fuels.
III
Always use the sight glass level to verify oil fill; for system oil change, run compressor momentarily to distribute oil,
then check level again. Do not overfill compressor.