SECTION 4: OPERATION
VIPER DIESEL
PAGE - 14
090058-OP_r0 (AUGUST-2014)
VANAIR MANUFACTURING, INC.
(800) 526-8817 • www.vanair.com
on the display. Once the problem is
corrected, the message can be cleared by
holding the Up button.
4.6.6 SERVICE INTERVALS
The controller will remind the user of periodic
service intervals. Once the package has
been serviced, the message can be cleared
by holding the Up button.
4.7 OPERATING CONDITIONS
1. Operate only in well-ventilated areas.
Exhaust fumes can be lethal.
2. Ensure there are no obstructions on
cooling air intakes at both ends of the
machine.
3. Do not leave anything resting on top of
the machine. Hot engine exhaust and
cooling air will generate high heat.
4. Be sure to leave sufficient room around
the machine for cooling air. See
Figure
3-1
.
5. Operate machine with top cover closed to
avoid engine exhaust fumes and heat
from being deflected.
6. Refer to specifications for operating
parameters, speeds, etc.
4.8 EXTREME CONDITIONS
When operating in extreme cold or hot
conditions, in the presence of high humidity,
or at a high altitude, extra attention should be
given to any indication that could lead to a
serious problem. Preventative safeguards
exist that can minimize the possibility of
malfunctions that are prone to occur under
certain ambient conditions. Refer to
Section
6.3, Extreme Condition Operation
, for
additional information on variable ambient
operating conditions, and adjustment
adaptations that can be made accordingly.