background image

1.5.4 Serial and Reverse Serial reader

When in Serial or Reverse Serial mode, the MIFARE card serial number (CSN) is read by the reader.

1.6 Reader re-programming

The ACTpro MIFARE readers ship from the factory pre-configured to read Vanderbilt MIFARE cards 
and fobs. The ACTpro MIFARE reader can also be reconfigured for serial or reverse-serial by 
repositioning the jumpers. (See 

Reader configuration

 on the previous page.)

On sites with an existing installation of MIFARE cards, it may be necessary to re-program MIFARE 
readers so that data on the existing MIFARE cards can be read. The ACTpro MIFARE readers are re-
programmed using a programming card.

The programming card can be generated on site using ACTenterprise software and an ACTpro USB 
reader (

ACTinstall > Advanced Setup > Card Configuration > MIFARE format

). You will require 

the following information on how the existing cards are encoded before generating the programming 
card: Data Format, Data Orientation, Start and End Byte Position, and Read/Write Keys.

To re-program an ACTpro MIFARE reader the programming card must be presented to the reader after 
power up and while the LED is Red. The ACTpro MIFARE reader will acknowledge the re-programming 
by playing an ascending note tune. (Configuration is held in non-volatile memory.)

Readers that have been re-programmed may be reset to read Vanderbilt-issued MIFARE cards and 
fobs with a Default Programming Card.

ACTpro MIFARE readers that have been programmed to read third-party MIFARE cards and fobs will 
play a series of ascending notes after being powered up in addition to the standard beep codes, this is 
to indicate that it no longer reads the MIFARE cards and fobs issued by Vanderbilt.

1.6.1 Backlight operation – MF1050e

The MF1050e ACTpro MIFARE Reader has backlight illumination of the keypad. The default operation 
is for the illumination to be switched on. During installation the back light operation may be switched off 
or changed to automatic. In automatic mode the keypad is illuminated for 20 seconds on a key press or 
when a card is presented to the reader.

To change the backlight operation: Power up the reader. The LED on the top right hand side will cycle 
through green, blue and red, and back to blue. While the LED is red, enter the code below for the 
required operation. The code must be completely entered while the LED is red.

 

l

Always on (Default): X014000

 

l

Always Off: X014001

 

l

Automatic: X014008

Note:

 The backlight operation for the MF1030PM is controlled by jumpers marked 

LED

. See 

LED 

control

 on page 13.

1.6.2 Buzzer operation

The internal buzzer is activated by applying 0V to the Buzz PIN. The buzzer activates 4 seconds after 
the 0V is applied and sounds continuously until the 0V is removed (external buzzer control is not 
available on the MF1030e).

1.6.3 Power On beep codes

The Output Data Format and the Sector/Serial Operation of the reader can be determined by the beeps 
generated by the reader after power is applied. The reader will generate two sets of beeps, the first 
indicating the Output Data Format and the second set of beeps indicating Sector or Serial Operation. 
The first set of beeps will occur while the LED is green, the second set of beeps occur half a second 
later while the LED is blue.

ACTpro MIFARE Readers – Installation Guide

Overview

© Vanderbilt 2018

10

A-100500-b

02.08.2018

Summary of Contents for ACTpro MIFARE Classic MF1030e

Page 1: ...ACTpro MIFARE Readers Installation Guide Document ID A 100500 b Edition date 02 08 2018 ...

Page 2: ...ess written authorization nor to use it for any purpose other than for which it was delivered to him MIFARE and MIFARE Classic are trademarks of NXP B V Hereby Vanderbilt International IRL Ltd declares that this equipment type is in compliance with the following EU Directives for CE marking Directive 2014 30 EU Electromagnetic Compatibility Directive Directive 2014 53 EU Radio Equipment Directive ...

Page 3: ...eration MF1030PM MF1040e MF1050e 9 1 5 2 Operation MF1030e 9 1 5 3 Sector reader 9 1 5 4 Serial and Reverse Serial reader 10 1 6 Reader re programming 10 1 6 1 Backlight operation MF1050e 10 1 6 2 Buzzer operation 10 1 6 3 Power On beep codes 10 2 Mounting instructions 12 2 1 MF1030PM 12 2 1 1 Panel mount reader connections to the ACTpro door controllers and door stations 13 2 1 2 LED control 13 2...

Page 4: ...for Wiegand or Clock Data output l Configurable backlight MF1050e only 1 2 Technical specification MF1030e MF1030PM MF1040e MF1050e Connections Pigtail Terminal Block Terminal Block Terminal Block Dimensions W x H x D 37 x 120 x 15mm 63 x 58 x 23mm 95 x 128 x 19mm 95 x 128 x 21mm Mounting Mullion Panel Flush or Surface Flush or Surface Weight 150g 65g 142g 155g Power Supply 12V DC 24V DC 12V DC 24...

Page 5: ...d only Card only Card PIN ACTpro MIFARE readers must be powered from a fused AC DC PSU 12 24V 1A maximum If the reader is used in a manner not specified in this document the protection provided by the reader may be impaired 1 3 Reader connections 1 3 1 MF1040e MF1050e X Sector Serial operation jumper ACTpro MIFARE Readers Installation Guide Overview Vanderbilt 2018 5 A 100500 b 02 08 2018 ...

Page 6: ...y Unused E 0V GND Black 1 3 3 CAT5 6 colour code The following is the suggested colour coding if using CAT5 or CAT6 cabling Reader Output Colour Sense White Green Clock D1 Green Data D0 Blue 12V Orange 0V GND White Orange Red LED Brown Green LED White Brown Orange Purple Programming Sector Serial ISP Grey Unused ACTpro MIFARE Readers Installation Guide Overview Vanderbilt 2018 6 A 100500 b 02 08 2...

Page 7: ...rite bead must be attached to the reader connection cable as close as possible to the reader terminal block Wind the reader connection cable around the ferrite bead twice tightly 1 4 2 Clock Data entry reader A Buzzer input not available on MF1030e E 12V Red B SENSE White F 0V GND Black C CLOCK D1 Green G RED Brown D DATA D0 Blue H GREEN Yellow ACTpro MIFARE Readers Installation Guide Overview Van...

Page 8: ...ue H GREEN Yellow 1 4 4 Wiegand entry reader IMPORTANT To put ACTpro MIFARE readers into Wiegand mode connect the SENSE on the reader to 0V GND A Buzzer input not available on MF1030e E 12V Red B SENSE F 0V GND Black White C CLOCK D1 Green G RED Brown D DATA D0 Blue H GREEN Yellow ACTpro MIFARE Readers Installation Guide Overview Vanderbilt 2018 8 A 100500 b 02 08 2018 ...

Page 9: ... desired operation and re apply power Sector Serial Reverse Serial Connect pins 1 2 Connect pins 2 3 Do NOT connect jumper 1 5 2 Operation MF1030e The operation of the MF1030e is selectable via cable configuration To change the operation power down the reader change the Orange and Purple cable for the desired operation and re apply power Colour Sector Serial Reverse Serial Orange 0V 0V Not Connect...

Page 10: ... up in addition to the standard beep codes this is to indicate that it no longer reads the MIFARE cards and fobs issued by Vanderbilt 1 6 1 Backlight operation MF1050e The MF1050e ACTpro MIFARE Reader has backlight illumination of the keypad The default operation is for the illumination to be switched on During installation the back light operation may be switched off or changed to automatic In au...

Page 11: ...le beep Wiegand 37 bit output Note If the reader has been re programmed see Reader re programming on the previous page then a series of notes is played after the second beep set this indicates that the default programming to read ACTpro MIFARE cards has been changed ACTpro MIFARE Readers Installation Guide Overview Vanderbilt 2018 11 A 100500 b 02 08 2018 ...

Page 12: ...l 2 Place the ACTpro MIFARE panel mount reader over the four studs 3 Use the four M3 washers and nuts supplied with the product to secure the reader to the audio entry panel 4 Use the wiring diagram below to connect the reader to the controller 5 When wiring is complete place the front cover back onto the audio entry panel 6 Apply power to the controller and test the reader with a card or fob Vand...

Page 13: ... turn green on access granted and red on access denied When the jumper is connected between LED and ON the blue LED on the front of the reader will remain on while in standby It will turn green on access granted and red on access denied 2 1 3 Wiring for Clock Data Wiegand reader The standard wiring colours for ACTpro MIFARE readers are shown below Readers should be a maximum of 100m apart when pow...

Page 14: ...to the surface mount collar D Place the cap onto the unit and push firmly in place 2 2 2 Flush mount A Remove spacers before mounting B Prepare the mounting surface to receive sub surface terminals Mount the flush mount collar on the wall using the fixing kit supplied in the box C Place the reader keypad onto the surface mount collar and clip down into place ACTpro MIFARE Readers Installation Guid...

Page 15: ...te before spacers are broken away by installer View B shows spacer stacking A Standard pattress box B C Attach the mounting plate to the pattress using the screws supplied C Ensure the correct spacers B have been used to bridge the gap between the mounting plate and the fixing wings of the pattress box to avoid the mounting plate being distorted D Place the reader keypad onto the surface mount col...

Page 16: ...2 3 MF1030e Screw unit to the surface Place caps on to the unit and push firmly into place ACTpro MIFARE Readers Installation Guide Mounting instructions Vanderbilt 2018 16 A 100500 b 02 08 2018 ...

Page 17: ...erbilt International Ltd Clonshaugh Business and Technology Park Clonshaugh Dublin D17 KV 84 Ireland vanderbiltindustries com contact Vanderbilt 2018 Data and design subject to change without notice Supply subject to availability Document ID A 100500 b Edition date 02 08 2018 ...

Reviews: