2.1.1 Panel mount reader connections to the ACTpro door controllers and door stations
A
Jumper pins 1 and 2
Sector operation
B
Jumper pins 2 and 3
Serial operation
No jumper
Byte reversed serial operation
2.1.2 LED control
The standby LED on the front of the reader can be configured using the jumper. When the jumper is
connected between LED and OFF, the blue LED on the front of the reader will remain off while in standby.
It will turn green on access granted and red on access denied.
When the jumper is connected between LED and ON, the blue LED on the front of the reader will remain on
while in standby. It will turn green on access granted and red on access denied.
2.1.3 Wiring for Clock & Data / Wiegand reader
The standard wiring colours for ACTpro MIFARE readers are shown below.
Readers should be a maximum of 100m apart when powered from +12V.
White
SENSE
Green
CLOCK & DATA 1
Blue
DATA / DATA 0
Red
+12V
Black
0V
Brown
RED LED
Yellow
GREEN LED
Orange
BUZZER Ctrl
ACTpro MIFARE Readers – Installation Guide
Mounting instructions
© Vanderbilt 2018
13
A-100500-b
02.08.2018