PROTECTING SEVERAL WINDOWS BY ONE DETEC-
TOR 

Detector can protect several windows in one room if the win-
dows  are  within  the  coverage  area.  Make  independent  DRC 
test  for  each  window  to  be  protected.  Follow  the  procedure 
above for each window. The detector shall be set to the lowest 
Zone number that is the longest range from the detector. 

TIMEOUT 

Both  the  AGB800  detector  and  ADT700  tester  are  equipped 
with  a  timeout  feature.  The  AGB800  will stop  the  DRC mode 
and  the  ADT700  will  switch  off  power  if  no  activity  has  hap-
pened within 3

–4 minutes. 

D/N CONTROL (Day/Night) 

The D/N makes it possible to remote control the alarm indica-
tions  of  the  detectors  and  remote  reset  during  DAY->NIGHT 
transition. The D/N increases the security of the detector, as it 
enables the alarm indications to be concealed in NIGHT mode 
without any influence on the relay function.  

SELF-TEST 

Detector is continuously checking all vital parts responsible for 
proper  detection  of  glass  break  signal  using  internal  self-test 
procedure.  

Issued by Vanderbilt 

Clonshaugh Business and Technology Park 
Clonshaugh, Dublin 17 
D17 KV84, Ireland 
www.vanderbiltindustries.com 
Doc ID: I-200253       Edition Date: 01.05.2017 

UNDERSTANDING THE LED WHEN THE DETEC-
TOR IS IN OPERATION 

LED 

Detector status 

Flashes 1

–3 times 

when powered ON 

Indication of range setting after power-on 

Off 

Normal state, no alarms 

Permanently on 

Intrusion detected 

– if detector in Latch 

mode 

Permanently on 
with 1 dip per 3s 

Masking detected 

Permanently on 
with 2 dips per 3s 

Low supply voltage or self-test failure 

UNDERSTANDING THE LED WHEN TESTING THE 
DETECTOR WITH ADT700 TESTER 

LED 

Detector status 

Flickers 

In test mode 

Flickers and blinks 

In calibration mode 

Flashes 1.5s 

Confirms received signal 

Blinks slowly 1 time each  
2.5s after calibration 

Set range setting to Zone 1 (4

–9m) 

Blinks slowly 2 times each  
2.5s after calibration 

Set range setting to Zone 2 (2

–4m) 

Blinks slowly 3 times each 
2.5s after calibration 

Set range setting to Zone 3 (1

–2m) 

TROUBLESHOOTING 

Detector does not respond 

  Check the supply voltage and polarity 

LED permanently on 

  Switch off the detector for a short period 

  Check if LED is in latching mode (DIP1=ON) 

LED permanently on with 2 dips per 3 s 

  Check supply voltage 

– should be higher than 7 V 

No alarm 

  Check the INTRUSION and FAULT relay wiring 

  Check the alarm loop wiring 

TECHNICAL DATA 

Type (thickness) of protected glass 

Float (4mm), laminated P2, P4 (4mm + 4mm) 

Size of protected glass 

Min 40 × 40 cm 

Max range 

9m radius/165° 

Range setting 

Zone 1 = 4

–9m 

Zone 2 = 2

–4m 

Zone 3 = 1

–2m 

Supply voltage 

7

–30V DC 

Max. voltage ripple 

2 Vpp at 12V, 4 Vpp at 24V 

Voltage monitoring 

Fault signaled at < 7V  

Current consumption quiescent state 

12mA @ 12V, 7.3mA @ 24V 

D/N signal levels 

DAY = D/N open or < 2.5V, NIGHT = D/N > 2.5V 

INTRUSION output, FAULT output 

Relay 

INTRUSION and FAULT relay contact rating 

50mA, 50V 

DC/peak AC, Rs ≤ 30Ω 

TAMPER contact rating 

50mA/50V DC/peak AC 

Intrusion/fault indication 

LED 

Environmental class  

EN50130-5:2011, VdS 2110 Class I 

Operating temp. range 

+5°C to +40°C 

Operating humidity range 

Max. 93% RH 

Housing material 

Plastic ABS, white 

Dimensions [WxHxD] 

69 x 110 x 39 mm 

Security grade 

EN 50131-2-7-1:2012/A1:2013, Grade 2, VdS class B 

Approvals  

 

 

ORDERING INFORMATION 

Type  

Art No. 

Description  

Weight 

AGB800

 

V54535-Z130-A100

 

Acoustic glass break detector G2

 

0.126Kg

 

Accessory

 

 

 

 

ADT700

 

N54535-Z100-A100

 

Acoustic glass break tester

 

0.743Kg

 

 

 