PP500 Installation Guide
11
ENG
Preset Configurations (short commands)
In programming mode, you can select different
configurations by using short codes. After select
-
ing the pre-defined configuration the reader will
return to programming mode.
These are key presses and after pressing A there
is only one key press between values 0 to 9.
Com-
mand
Function
A1
Preconfigured interface BCLINK (for
Vanderbilt Entro)
A2
Preconfigured interface 12 (26 bit
Wiegand)
A3
Preconfigured interface BE (Clock &
Data)
A4
Preconfigured interface 59 (48 bit
Wiegand for Granta)
The Preconfigured interfaces is stored in non-vola
-
tile memory. Any other parameters such as LED
control and horn control will be defined later and
will only apply for A2, A3 and A4.
A3 Preconfigured is interface BE (Clock & Data),
with external control of Red LED, Green LED and
Horn. Also, the yellow LED is not active at all,
showing no indication of noise or key presses.
Summary of Contents for PP500-Cotag