9
Appendix
User rights
44
Vanderbilt
Compact Keypad User Manual
I-200004-1
01.10.2015
9
Appendix
9.1
User rights
Based on the operational features of the system, described below, users have
rights attributed to the user profiles. The installation engineer will inform users of
their user rights assigned to each user profile. Depending on how the system has
been programmed, users may have rights to all or some of these features.
User rights
User Profile
Default
User type
Description
Fullset
Limited
Standard
Manager
The FULLSET operation fully sets the alarm system
and provides full protection to a building (opening of
any alarm zones activates the alarm).
On selecting FULLSET, the buzzer sounds and the
keypad display counts down the exit time period. Exit
the building before this time period has expired.
When the exit time period has expired, the system is
set and opening of entry/exit zones starts the entry
timer. If the system is not Unset before the entry timer
expires, the alarm is activated.
Partset A
Standard
Manager
The PARTSET A option provides perimeter protection
to a building while allowing free movement through the
exit and access areas.
Zones that have been classified as EXCLUDE A
remain unprotected in this mode. By default, there is no
exit time; the system sets instantly on selection of this
mode. An exit timer can be applied to this mode by
enabling the Partset A timed variable.
Partset B
Standard
Manager
The PARTSET B option applies protection to all zones
except those that have been classified as EXCLUDE B.
By default there is no exit time; the system sets
instantly on selection of this mode. An exit timer can be
applied to this mode by enabling the Partset B timed
variable.
Forceset
Standard
Manager
The FORCESET option is presented on the keypad
display when an attempt is made to set the system
while an alarm zone is faulty or still open (the top line of
the display shows the open zone).
Selecting this option sets the alarm and inhibits the
zone for that set period.
Unset
Limited
Standard
Manager
The UNSET operation unsets the alarm. This menu
option is only presented on the keypad after an alarm
has been activated and a valid user code has been
entered.
Restore
Standard
Manager
The RESTORE operation restores an alert condition on
the system and clears the alert message associated
with that alert condition.
An alert condition can only be restored after the zone(s)
or fault(s) that triggered the alert condition have been
restored to their normal operating state and the
RESTORE option in user programming is selected for
that zone.
Isolate
Standard*
Manager
Isolating a zone deactivates that zone until such time
as the zone is de-isolated. All zone types on the can
be isolated.
Use of this feature to deactivate faulty or open zones