background image

 

8

   

V42

 

6

 

Relay terminal blocks  

Max 30m cable. 

 

For locks with failsafe (power to lock) function, connect 
lock to terminal 5, not 3. 

Technical data 

Power voltage:

12-24 V AC/DC. 

Power consumption:

8 mA quiescent. 

Relay output:

Voltage free relay, max. 
1A, 28V DC.  
Cable < 30m. 

Temperature Range:

-35° to +55°C. 

Environment:

Indoor – or outdoor use 
(IP54 design). 

Dimension (hxwxd):

140 x 80 x 40 mm. 

Recommended mounting height 1200 – 1400 mm. If 
the code lock is to be flush mounted, the flush 
mounting unit BB3 should be used. 

Power supply 

Ensure that the power supply is stable and within the 
rated voltage of the unit. Use an uninterrupted power 
supply (UPS) to ensure a continuous function of the 
unit in the event of power dips on the mains supply. 

 