RS−P Solar Water Pump Controller User Manual
Chapter 1 System configuration
5
the whole solar panels :
Maximum Power (Pm)
1300W
130W*10
Open Circuit Voltage (Voc)
775V
155.0V*5
Short Circuit Current (Isc)
2.56A
1.28A*2
Maximum Power Voltage
(
Vpm
)
604V
120.8V*5
Maximum Power Current (Ipm)
2.16A
1.08A*2
Maximum System Voltage
----
1000V
1.4 solar water pump controller selection
There are too types of solar water pump controllers. One is 2D,the other is 4D.
RS-P-2D
□□□
Single-phase AC power & PV DC power
Power (W)
600
800
1200
1700
2500
MotorPower (kW)
0.55
0.75
1.1
1
.
5
2.2
Outpu
Voltage (V)
Three
−
phase AC 220V (adjustable area 0 ~ Rated Input AC voltage)
Rated current (A)
2.9
4.5
6.0
7.5
10
Overload
150%: 1 minute, 180%: 10 seconds, 200%: 0.5 second, interval: 10 minutes (inverse time
lag feature)
Input
Rated
Single or Three
−
phase 200~240V 50Hz/60Hz ; PV Area VocDC410V
±
30V
Allowable
AC 180V to 260V, Voltage imbalance:
≤
3%, allowable frequency fluctuation:
±
5% ; MPPT
Area DC300
~
360V
Rated
current
(A)
AC1/3PH
5.5 / 3.5
9.2 / 5.4
11.4 / 7.2
14.5 / 9
23 / 12
DC
3.5
5.4
7.2
9
12
Protection class
IP20
Cooling mode
Natural
−
cooling
Forced air convection cooling