TS
−
I Special servo drive for hybrid electro-hydraulic system of injection molding machine User Manual
Chapter 4 Parameters and debugging of servo drive
45
Function
code
number
Function code name
Factory
setting
Setting range
Unit
Prop
erty
Function code selection
User
setting
P8.09 Multi pump type
0000
0000
~
1113 /
×
Units bit: merging type
0: Single pump
1: Multi pump merging
2: Multi pump merging & splitting;
3: Multi mode combination;
Tens bit: Converging control
0: IO point control
1: Auto combination of driver;
Hundreds bit: IO merging signal
effective
0: Enabled at high level, enter
merging state
1: Enabled at low level, enter
merging state
Thousands bit: Stop mode(enabled
when tens bit is 0)
0: At IO point control, the auxiliary
pump stops according to P8.12
~
P8.14
1: Auxiliary pump does not stop
P8.10 Total number of merging pump
0
0
~
16 pcs
×
P8.11 Pump function in system
0
0
~
4 /
×
0: Merging pump
1: Merging/splitting control pump
2: Merging / splitting following pump
3: Splitting control pump
4: Splitting following pump
P8.12 Min control speed for stopping
auxiliary pump
200
0
~
500 rpm
○
P8.13 Pressure threshold during
stopping of auxiliary pump
95.0
0
~
100.0 %
○
P8.14 Delay time for stopping of
auxiliary pump
0.30
0.0
~
10.00
○
P8.15 Pump capacity to total system
capacity
100
0
~
100.0 %
○
P8.16 Pump capacity for stopping
running
5.0 2.5
~
10.0 %
○
P8.17 Main pump speed when auxiliary
pump starts up
50 0
~
500 rpm
○
P8.18
Effectiveness of merging /
splitting signal
0 0
~
1 /
×
0: Merging at high level and splitting
at low level
1: Merging at low level and splitting
at high level
P8.19
Total number of merging pump in
splitting unit
0 0
~
16 pcs
×
P8.20
Pump capacity of total capacity of
splitting units
100.0
0
~
100.0 %
○
Group P9 Motor Parameter
P9.00 Motor
type
0 0
~
1 /
×
0:Surface mounted permanent
magnetic synchronous motor
1:Embedded permanent magnetic
synchronous motor
Summary of Contents for TS-I Series