CT-6500 Series 2 Operating Instructions
63
9.19 CT-6500 Channel Configuration
The CT-6500 is available with 3 or 6 or 12 contact inputs. Most common timing conditions
require the user to use only 3 contact timing channels and one travel transducer channel. There is
no need to print more than 3 timing channels and one transducer channel on the graphic and
tabulated report. The CT-6500 will always default to 3 contact channels (channel 1, 2 and 3) and
one transducer channel (transducer channel #1) when the user first turns on the unit. The user
can always turn on the rest of the timing channels and transducer channels by following the steps
in the table below:
Table 24.0 Channel Configuration
STEP
OPERATION
ACTION
DISPLAY
1
SELECT SET UP MENU.
PRESS # 3 KEY.
1. ANALYSIS POINT
2. MEASUREMENT UNITS
3. SAVE / RESTORE
4. NEXT PAGE
2
SELECT NEXT PAGE.
PRESS # 4 KEY.
1. SHOT DESCRIPTION
2. NUMBER OF CHANNELS
3. SET DATE & TIME
4. NEXT PAGE
3
SELECT NUMBER OF CHANNELS.
PRESS # 2 KEY.
NUMBER OF CHANNELS
1. 3 CONTACT
2. 6 CONTACT
3. 12 CONTACT
4
SELECT 3 CHANNELS OR 6
CHANNELS OR 12 CHANNELS.
PRESS # 1, OR 2 OR
3 KEY.
1. TRANSDUCER 1
2. TRANSDUCER 1 , 2
3. TRANSDUCER 1 , 2 , 3
5
SELECT 1 TRANSDUCER, OR 2, OR 3.
PRESS #1, OR #2,
OR #3.
1.RUN TEST 06/10/07
2.GET RESULTS 20:10:01
3.SETUP
4.DIAGNOSTIC
Summary of Contents for CT-6500 2 Series