REV 3
WRM-10P AND WRM-40 USER’S MANUAL
21
Press the
[1]
key (
COPPER, Tk=234.5
) to select copper as the winding material.
Continue to step d
.
Press the
[2]
key (
ALUMINUM, Tk=225
) to select aluminum as the winding
material.
Continue to step d.
Press the
[3]
key (
MANUALLY ENTER Tk
) to manually enter the Tk value. The
following screen will be displayed:
You can increase the Tk value by 0.5
°
C increments by pressing the
[PAPER
∧
Contrast]
key.
You can decrease the Tk value by 0.5
°
C increments by pressing the
[PAPER
∨
Contrast]
key.
Press the
[ENTER]
key to confirm the temperature setting.
Continue to step e.
2.
NO
Press the
[2]
key (
NO
) if you do NOT wish to convert readings to standard
temperature.
Continue to step e.
e.
The following screen will be displayed:
Use the
[PAPER
∧
Contrast]
and
[PAPER
∨
Contrast]
keys to adjust the D.U.T.
(Device Under Test) temperature.
Press the
[ENTER]
key to confirm the D.U.T. temperature setting.
f.
The following screen will be displayed:
Use the
[PAPER
∧
Contrast]
and
[PAPER
∨
Contrast]
keys to adjust the
reference temperature.
Press the
[ENTER]
key to confirm the reference temperature setting.
REFERENCE TEMP:
85.0
°
C 185.0
°
F
↑↓
to adjust temp
“ENTER” to accept
D.U.T. TEMP
25.0
°
C 77.0
°
F
↑↓
to adjust temp
“ENTER” to accept
Tk:
230.0
°
C
↑↓
to adjust Tk
“ENTER” to accept