Page 3
For technical questions, please call 1-888-866-5797
Item 63127 63147
Wiring Instructions
Read the ENTIRE IMPORTANT SAFETY INFORMATION section
at the beginning of this document including all text under
subheadings therein before set up or use of this product.
TO PREVENT SERIOUS INJURY AND DEATH FROM ELECTRIC SHOCK:
DEVICE TO BE INSTALLED BY QUALIFIED PERSON.
CONDUCTORS MUST BE DE-ENERGIZED BEFORE WIRING.
1. Select proper wire size and
type for load and application.
Use only applicable round cord
and cables per electrical codes.
Device to be used with 16-3 cord
and the following cord types:
SJT group, ST group, S group,
SE group, SJ group, SJE group
USE COPPER WIRE ONLY.
2. Wiring preparation:
a. Select correct end of cord
to ensure easy insertion
of conductors. (Conductor
sequence is important.)
b. Strip cord jacket and
conductors as shown in
Figure A. Twist strands.
(Do not tin conductors.)
3. Open the connector by
separating its body and shell.
1RWHWKHSOXJFRQQHFWRU
is keyed to the shell.)
4. Wiring method:
a. Slip outer shell onto the
cord. Adjustment of cord
clamps may be necessary
depending on cord size.
b. Insert all conductors into
identified terminal pockets.
1.
Green
wire to
green
terminal pocket.
2.
White
wire to
silver
terminal pocket.
3.
Black
wire to
black
terminal pocket.
c. Tighten terminal screws
to 20 inch lb.
5. Assembly:
a. Slip shell into front section
by aligning key on body
with key in shell.
b. Evenly tighten
assembly screws to 14 inch lb.
c. Evenly tighten cord grip screws
to 14 inch lb.