OWNER’S MANUAL

VENTING
INSTALLATION

Continued

HIGH ALTITUDE
INSTALLATION

Your Vanguard direct-vent fireplace has
been AGA tested and approved for eleva-
tions from 0-2000 feet and CGA certified
for elevations from 0-4500 feet.

When installing this fireplace at an elevation
above 2000 feet (in the USA), you may need
to decrease the input rating by changing the
existing burner orifice to a smaller size. Re-
duce input 4% for each 1000 feet above sea
level. Check with your  local gas company for
proper orifice size identification.

When installing this fireplace at an eleva-
tion above 4500 feet (in Canada), check
with local authorities.

Consult your local gas company to help de-
termine the proper orifice for your location.

For assistance with any high altitude instal-
lation contact DESA International’s Tech-
nical Service Department at 1-800-DESA-
LOG (1-800-337-2564).

PARTS LISTS FOR VENTING
KITS AND COMPONENTS

Vanguard Rigid Venting

Number Description

BGFVK

Basic Ground Floor Rigid Vent Kit

Includes: 7" x 60

°

 Elbow, Extended

Adjustable Horizontal Termination,
Wall Thimble and 14 Screws

CVK

Corner Vent Kit

Includes: 7" x 30º Elbow, 7" x 90º
Elbow, 7" Adjustable Galvanized
Pipe (7-12"), 6" Pipe, Wall
Thimble, Horizontal Termination,
RTV Silicone and 20 Screws

BVK

Basement Rigid Vent Kit

Includes: 7" x 30

°

 Elbow, 7" x 4'

Galvanized Pipe, 7" x 90

°

 Elbow, 7"

Adjustable Galvanized Pipe (7-12"),
Wall Thimble, Horizontal Termi-
nation, RTV Silicone and 20 Screws

SVK

Snorkel Rigid Vent Kit

Includes: 7" x 30

°

 Elbow, 7" x 4'

Galvanized Pipe, 7" x 90

°

 Elbow, 7"

Adjustable Galvanized Pipe (7-12"),
Wall Thimble, 36" Snorkel Termi-
nation, RTV Silicone and 28 Screws

Number Description

RVF

Roof Rigid Vent Kit

Includes: Flue Restrictor, Storm
Collar, 7" x 30

°

 Elbow, 7" x 4'

Galvanized Pipe, 7" x 2' Galva-
nized Pipe, 7" Adjustable Galva-
nized Pipe (7-12"), Firestop Sup-
port, Roof Flashing, RTV Silicone,
Vertical Termination, and 26 screws

D1000

7" x 12" Galvanized Coaxial
Pipe (6 pcs.)

D1010

7" x 24" Galvanized Coaxial
Pipe (6 pcs.)

D1020

7" x 48" Galvanized Coaxial
Pipe (6 pcs.)

D1030

7" Adjustable (7-12")

Galvanized Coaxial Pipe

(6 pcs.)

D1050

7" x 6" Galvanized Coaxial
Pipe (6 pcs.)

D2000

7" x 90

°

 Elbow (6 pcs.)

D2010

7" x 45

°

 Elbow (6 pcs.)

D2020

7" x 30

°

 Elbow (6 pcs.)

D2030

7" x 60

°

 Elbow (6 pcs.)

D3000

Wall Strap/Offset Support
(6 pcs.)

D3010

Storm Collar (6 pcs.)

D3020

Wall Thimble (6 pcs.)

D3040

Vertical Vent Termination Cap

D3050

Vertical Restrictor (6 pcs.)

D3060

Ceiling Firestop/Support
(6 pcs.)

D3070

Rectangular Horizontal Rigid
Vent Termination Cap

D3071

Adjustable Horizontal Rigid

Vent Termination Cap

D3090

Cathedral Ceiling Support Box

D4000

Roof Flashing 6/12-9/12

D4010

Roof Flashing 9/12-12/12

D5000

Wood/Vinyl Siding Standoff
(6 pcs.)

SIMPSON DURA-VENT
GS 4" x 6 

5

/

"

Number Description

Available from DESA International:

SD2040

Simpson Dura-Vent GS
30

°

 Elbow (6 pcs.)

SD2050

Simpson Dura-Vent GS
60

°

 Elbow (6 pcs.)

Available from Simpson Dura-Vent only:

902

7" x 48" Pipe

903

7" x 36" Pipe

904

7" x 24" Pipe

906

7" x 12" Pipe

907

7" x 9" Pipe

908

7" x 6" Pipe

911

7" Adjustable (11"-14 

5

/

8

") Pipe

940

Wall Thimble

941

Cathedral Ceiling Support Box

943

Roof Flashing 0/12-6/12

943S

Roof Flashing 7/12-12/12

945

7" x 45

°

 Elbow

950

Vinyl Siding Standoff

953

Storm Collar

963

Ceiling Firestop

981

36" Snorkel Termination

984

Horizontal Termination Vent Cap

988

Wall Strap

990

7" x 90

°

 Elbow

991

Vertical High Wind Termination

Vanguard Flexible Venting 

(Cont.)

Number Description

BFGFVK

Basic Flex Ground Floor Vent Kit

Includes: Flex Adapter, 7" x 2'
Flexible Pipe, 4" x 2' Flexible
Pipe, Wall Thimble, Horizontal
Termination, (2) Spacer Springs,
(2) 4" Hose Clamps, (2) 7" Hose
Clamps, and 10 Screws

Vanguard Rigid Venting 

(Cont.)

Vanguard Flexible Venting

Number Description

FGFVK

Flex Ground Floor Vent Kit

Includes: Flex Adapter, 7" x 4'
Flexible Pipe, 4" x 4' Flexible Pipe,
Wall Thimble, Horizontal Termi-
nation, (4) Spacer Springs, (2) 4"
Hose Clamps, (2) 7" Hose Clamps,
RTV Silicone, and 10 Screws

D1040

7" x 25' Coaxial Flex Pipe
with Spacer Springs

D3080

Rectangular Horizontal
Flex Termination Cap

D4020

Flex Connector (6 pcs.)

D4030

Flex Wall Thimble (6 pcs.)

D4040

4" Hose Clamp (6 pcs.)

D4050

7" Hose Clamp (6 pcs.)

Summary of Contents for BHDV34PB

Page 1: ...is tance or additional information consult a qualified installer ser vice agency or the gas supplier WARNING If the information in this manual is not followed exactly a fire or explosion may result ca...

Page 2: ...he glass door must be properly seated and sealed If this unit is not properly installed by a qualified service person with glass door properly seated and sealed gas leakage can occur Carbon Monoxide P...

Page 3: ...t PIEZO IGNITOR This fireplace has a piezo ignitor This sys tem requires no matches batteries or other sources to light fireplace Figure 1 Vanguard Direct Vent Fireplace BHDV Series Glass Door Assembl...

Page 4: ...3 34 3 4 34 1 4 20 Vertical Termination 19 Horizontal Termination CLEARANCES Minimum clearances to combustibles for the fireplace are as follows Back and sides 0 mm Perpendicular walls 6 152mm Floor...

Page 5: ...ept where stated otherwise Combustible material may be flush with the top front of fireplace with a maxi mum thickness of 3 4 Do not recess venting terminals into a wall or siding You must install a v...

Page 6: ...bove paved side walk or a paved driveway located on public property 84 inches 2133mm minimum M clearance under veranda porch deck 12 inches 305mm minimum N clearance above a roof shall extend a minimu...

Page 7: ...ination It is important to select the proper length of vent pipe for the type of termination you choose It is also important to note the wall thickness For Horizontal Termination Select the amount of...

Page 8: ...bows to the appliance adaptor with pipe seams oriented towards the wall or floor Twist lock Procedure The female ends of the pipes and fittings have four locking lugs indentations These lugs will slid...

Page 9: ...f the vent cap Position the vent cap in the center of the 7 1 2 or 10 hole on the exterior wall with the arrow on the vent cap pointing up Insure proper clearance of 1 to combustibles is maintained At...

Page 10: ...use with corner installation UP Horizontal Venting See information in Figure 17 for Vertical V and Horizontal H maxi mums and minimums The same amounts apply for flexible venting Note Figure 16 applie...

Page 11: ...max 8 min 8 min 20 max 20 max 8 max 20 max Venting with Two 90 Elbows Vertical V Horizontal H1 Horizontal H2 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max 20 max 20 max Figure 19 Horizontal Termi...

Page 12: ...uired clearances air space to combus tibles when passing through ceilings walls roofs enclosures attic rafters etc Do not pack air spaces with insulation Also note maximum vertical rise of the venting...

Page 13: ...y using a level Temporarily tack the support box in place through the inside walls and into the roof sheathing 4 Using tin snips cut the supportbox from the top corners down to the roofline and fold t...

Page 14: ...VENTING INSTALLATION Continued Venting with Two 90 Elbows Vertical V1 Horizontal H 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max Note Vertical V1 Vertical V2 20 max Figure 27 Vertical Rigid Venti...

Page 15: ...alvanized Coaxial Pipe 6 pcs D1020 7 x 48 Galvanized Coaxial Pipe 6 pcs D1030 7 Adjustable 7 12 Galvanized Coaxial Pipe 6 pcs D1050 7 x 6 Galvanized Coaxial Pipe 6 pcs D2000 7 x 90 Elbow 6 pcs D2010 7...

Page 16: ...nstall this fireplace as your primary heat source If you have acentralheatingsystem youmay run system s circulating blower while using fireplace This will help circulate the heat through out the house...

Page 17: ...see Figure 33 Route power cord through both plastic bushing s and plug the power cord into a properly grounded 3 prong wall receptacle near the firebox b If your fireplace system installation is rece...

Page 18: ...pt able alternative to test gauge connection Purchase the CSA AGA design certified equipment shutoff valve from your dealer WARNING A qualified ser vice person must connect fire place to gas supply Fo...

Page 19: ...ble gas line provided by installer from equipment shutoff valve to fireplace Route flexible gas supply line through one of the access holes on side of fireplace 3 Attach flexible gas line from gas sup...

Page 20: ...off valve see Fig ure 37 2 Open propane LPsupply tank valve for propane LPfireplace or main gas valve located on or near gas meter for natu ral gas fireplace 3 Make sure control knob of fireplace is i...

Page 21: ...place or heat and air conditioning ducts 5 Gently remove the cover of the ther mostat from the base Grasp the sides of the cover firmly and pull to separate from the base 6 Feed the electrical wires t...

Page 22: ...h terminal wires to a 9 volt alka line battery not included Place bat tery into the battery housing 3 Replace battery cover onto remote con trol unit Figure 45 Installing Alkaline Battery in Hand Held...

Page 23: ...48 4 Slide the left retainer bracket against the left side brick panel Loosely se cure the bracket screw This secures the left side brick panel 5 Install the right brick panel using the same method d...

Page 24: ...4 Place log 4 small round log on the pin on the right side of front log as shown in Figure 53 5 Place log 5 small log onto the front left part of the grate making sure the notches fit over the prongs...

Page 25: ...LO The burners will turn on and off automatically to maintain the comfort level you select The ideal comfort setting will vary by household depending upon the amount of space to be heated the output...

Page 26: ...ntrolled blower have an ON setting and an OFF setting The blower will only run when the switch is in the ON position In the OFF position the blower will not operate Note for DA3610TA Only If you are u...

Page 27: ...e To Turn Off Gas to Appliance page 25 see Troubleshooting pages 29 through 31 Figure 59 Pilot Assembly Figure 60 Typical Flame Pattern for models BHDV34NB and BHDV34PB Thermocouple Thermopile 3 8 to...

Page 28: ...gidity WARNING Turn off fireplace and let cool before cleaning CAUTION Youmustkeepcon trol areas burners and circulat ing air passageways of fireplace clean Inspect these areas of fire place before ea...

Page 29: ...oose at con trol valve 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holdi...

Page 30: ...e burner until air is removed from line Have gas line checked by local pro pane LP or natural gas company 3 Clean burner see Cleaning and Maintenance page 28 or replace burner orifice 1 Adjust the log...

Page 31: ...t blocked 3 Burner flame holes blocked OBSERVED PROBLEM Fireplace produces unwanted odors Fireplace shuts off in use Gas odor even when control knob is in OFF position Gas odor during combustion Dark...

Page 32: ...o disconnection when servicing controls Wiringerrorscancause improper and dangerous opera tion Verify proper operation af ter servicing Note Use only original replacement parts Thiswillprotectyourwarr...

Page 33: ...ure 4 5 w c 11 0 w c Thermal Efficiency 70 70 Dimension Inches mm HxWxD Fireplace Actual size of firebox Measurements do not 32 3 16 x 34 3 8 x 18 1 2 32 3 16 x 34 3 8 x 18 1 2 include nailing flanges...

Page 34: ...Oak G3004W Series Off White Paint Thehearthbasecreatesahandsomeriserfor the fireplace cannot be used with corner mantel Dimensions WxHxD 58 x61 2 x289 16 CORNER MANTEL GM200F Series Walnut Stained Har...

Page 35: ...es installation and removal quick and easy They are designed to go at the top and bottom of the glass door on BHDV units Note Remove the plastic film covering on strips before installing on fireplace...

Page 36: ...ND BHDV34PB ILLUSTRATED PARTS BREAKDOWN BHDV34NB BHDV34PB 48 31 3 1 2 3 4 6 6 36 5 5 6 5 11 Included in Hardware Pack 7 7 8 10 9 12 13 14 15 16 17 18 19 20 32 21 22 23 24 25 26 27 28 28 29 30 33 32 32...

Page 37: ...P 1 19 104498 01 Thermocouple 1 20 104499 01 Thermopile 1 21 104500 01 Ignitor 1 22 104501 01 Ignitor Bracket 1 23 104502 01 Ignitor Screw 1 24 104503 01 Ignitor Wire 1 25 104504 01 Burner Natural 1 1...

Page 38: ...airing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESS...

Reviews: