background image

9

105274

OWNER’S MANUAL

Figure 7 - Minimum Mantel Clearances When Using Hood

INSTALLATION

Continued

Figure 6 - Minimum Mantel Clearances Without Using Hood

MANTEL CLEARANCES

In addition to meeting noncombustible mate-
rial clearances, you must also meet required
clearances between fireplace opening and
mantel shelf. If you do not meet the clear-
ances listed below, you will need a hood.

Determining Minimum Mantel
Clearance

If you meet minimum clearance between
mantel shelf and top of fireplace opening, a
hood is not required (see Figure 6).

Determining Minimum Mantel
Clearance When using a Hood

If minimum clearances in Figure 6 are not
met, you must have a hood. When using a
hood there are still certain minimum mantel
clearances required. Follow minimum clear-
ances shown in Figure 7 when using hood.

Minimum Non-
Combustible 
Material 

Minimum Non-
Combustible 
Material Height 

Distances to 
Underside of
Mantel 

Top of Fireplace
Opening

Underside of
Mantel Shelf

Mantel Shelf

12"

8"

(A)

18"

8"

20"

14"

22"

16

3/4

"

24"

20"

All minimum 
distances are
in inches

Log Set
24"/30"/36" Models

18" Model

1

/2

"

6"

8"

10"

Minimum Non-
Combustible 
Material 

8"
Min.

12"

15"

18"

All minimum 
distances are
in inches

Log Sets
 All Models

20"

1

/2

"

6"

8"

10"

12"

Distances to 
Underside of
Mantel 

Hood
(GA6050, GA6052)

Top of Fireplace
Opening

Underside of
Mantel Shelf

Mantel Shelf

Figure 8 - Minimum Fireplace Clearances
If Installed at Floor Level

Figure 9 - Minimum Fireplace Clearances
Above Combustible Flooring

14"
Min.

Combustible 
Material 

Non-Combustible Material 

Hearth

5"
Min.

Combustible 
Material 

Hearth

Combustible
Material

5”
Min.

Continued

FLOOR CLEARANCES

A. If installing appliance on the floor level,

you must maintain the minimum dis-
tance of 14" to combustibles (see Fig-
ure 8).

B. If combustible materials are less than

14" to the fireplace, you must install
appliance at least 5" above the combus-
tible flooring (see Figure 9).

NOTICE: If your installation does
not meet the minimum clearances
shown, you must do one of the
following:
• operate the logs only with the

flue damper open

• raise the mantel to an accept-

able height

• remove the mantel

Hood
(GA6050, GA6052,
or GA6053)

Summary of Contents for UNVENTED (VENT-FREE) PROPANE/LP GAS LOG...

Page 1: ...amage Refer to this manual for correct installa tion and operational procedures For as sistance or additional information con sult a qualified installer service agency or the gas supplier WARNING This appliance is for installa tion only in a solid fuel burning masonry or UL127 factory built fireplace or in an approved ventless firebox It is design certified for these installations in accor dance w...

Page 2: ...closed heat buildup inside fireplace will cause glass to burst Also if fireplace opening has vents at the bottom you must open the vents before operating heater 9 You must operate this heater with a fire placescreeninplace Makesurefireplace screen is closed while running heater 10 This log heater is designed to be smoke less If logs ever appear to smoke turn off heater and call a qualified service...

Page 3: ...g Set Base Assembly Optional Remote Control Flame Adjustment Knob Optional Selector Switch PRODUCT FEATURES OPERATION This heater is clean burning It requires no outside venting There is no heat loss out a vent or up a chimney Heat is generated by realistic dancingyellowflames Thisheater is designed for vent free operation with flue damper closed It has been tested and ap proved to ANS Z21 11 2 st...

Page 4: ...pace as a space whose volume is less than 50 cubic feet per 1 000 Btu per hour 4 8 m3 per kw of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1 000 Btu per hour 4 8 m3 per kw of the aggregate inputratingofallappliancesinstalledinthat space Rooms communicating directly with the space in which t...

Page 5: ...tion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used ____________Btu Hr maximum the space can support ____________Btu Hr actual amount of Btu Hr used Example 51 200 Btu Hr maximum the space can support 79 000 Btu Hr actual amount of Btu Hr used The space in the above example is a confined space because the act...

Page 6: ...utdoors Provide extra fresh air by using ventilation grills or ducts You must provide two per manent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors orspacesopentotheoutdoors Thesespaces include attics and crawl spaces IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermostat controlledpowervent ...

Page 7: ...traffic areas in windy or drafty areas CAUTION This heater cre ates warm air currents These currents move heat to wall sur faces next to heater Installing heater next to vinyl or cloth wall coverings or operating heater where impurities such as to bacco smoke aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may discolor walls IMPORTANT Vent freeheatersaddmois ture to the...

Page 8: ...lace hood ac cessory GA6050 GA6052 or GA6053 see Acces sories page 25 18 Model Noncombustible material OK Less than 8 Noncombustible material must be extended to at least 8 See Between 8 and 12 above If you cannot extend material you must operate heater with flue damper open NOTICE Manual control heaters maybeusedasaventedproduct If so you must always run heater with chimney flue damper open If ru...

Page 9: ...ntel Shelf 12 8 A 18 8 20 14 22 163 4 24 20 All minimum distances are in inches Log Set 24 30 36 Models 18 Model 2 1 2 6 8 10 Minimum Non Combustible Material 8 Min 12 15 18 All minimum distances are in inches Log Sets All Models 20 2 1 2 6 8 10 12 Distances to Underside of Mantel Hood GA6050 GA6052 Top of Fireplace Opening Underside of Mantel Shelf Mantel Shelf Figure 8 Minimum Fireplace Clearanc...

Page 10: ...g fireplace with a working flue and constructed of non combustible material Ifyourheaterisamanuallycontrolledmodel you may use this heater as a vented product There are three reasons for operating your heater in the vented mode 1 The fireplace does not meet the clear ance to combustibles requirements for vent free operation 2 State or local codes do not permit vent free operation 3 You prefer vent...

Page 11: ...er base 5 Center heater base and logs front to back and side to side in fireplace 6 Carefully remove logs without moving heater base 7 Mark screw locations through one hole on each side of the mounting bracket see Figure 12 If installing in a brick bottom fireplace mark screw locations in mortar joint of bricks 8 Remove heater base from fireplace If installing optional control accessories do so at...

Page 12: ... freezing rain or sleet INSTALLATION Continued WARNING Never connect heater to private non utility gas wells This gas is commonly known as wellhead gas Installation must include a manual shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from heater see Figure 14 Apply pipe joint sealant lightly to male threads This will prevent ...

Page 13: ...or rect all leaks at once CAUTION Make sure exter nal regulator has been installed between propane supply and heater SeeguidelinesunderCon necting to Gas Supply page 12 CHECKING GAS CONNECTIONS TestPressuresEqualToorLessThan 1 2 PSIG 1 Close manual shutoff valve see Fig ure 15 2 Pressurize supply piping system by ei ther using compressed air or opening propane supply tank valve 3 Check all joints ...

Page 14: ...of chassis see Figure 17 Note 36 model has more features but fits on the chassis the same Log will fit securely on chassis IMPORTANT Make sure log does not cover any burner ports 2 Place lava rock around base of heater Figure 17 Installing Golden Oak One Piece Log Set Figure 18 Installing Golden Oak One Piece Log set Top View CAUTION After installation andperiodicallythereafter check to ensure tha...

Page 15: ... withafireplacescreeninplace Make sure fireplace screen is closed before running heater NOTICE During initial operation of new heater burning logs will give off a paper burning smell Open damper or window to vent smell This will only last a few hours Note Home owners generally prefer to operate their heater with the chimney damper closed This will put all the heat into the room However there may b...

Page 16: ...n Adjust flame adjust ment knob anywhere between HI and LO Slide the selector switch to the REMOTE position Note The burner may light if hand held remote ON button was on when selector switch was last turned off You can now turn the burner on and off with the hand held remote control unit IMPORTANT Do not leave the se lector switch in the REMOTE posi tion when the pilot is not lit This will drain ...

Page 17: ...ance These holes may become blocked with dust or lint Periodically inspect these holes for any blockage and clean if needed Blocked air holes will create soot MAIN BURNER Periodically inspect all burner flame holes with the heater running All slotted burner flame holes should be open with yellow flame present All round burner flame holes should be open with a small blue flame present Some burner f...

Page 18: ...r holder for dust and dirt see Figure 25 3 Blow air through the ports slots and holes in the burner Figure 25 Injector Holder On Outlet Burner Tube Burner Tube Injector Holder May Be Brass or Aluminum Depending on Model Primary Air Inlet Holes Shape of Holes May Vary by Model Burner Tube Pilot Assembly Pilot Air Inlet Hole Ports Slots Figure 26 Pilot Inlet Air Hole 4 Check the injector holder loca...

Page 19: ...onnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind base panel 4 Replace ignitor cable 5 Replace piezo ignitor 6 Replace piezo ignitor 7 Replace piezo ignitor 1 Turn on gas supply or open manual shutoff valve 2 Turn control knob to PILOT position 3 Press in control knob...

Page 20: ... requirements page 4 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local pro pane gas company 3 Observe minimum installation clear ances see pages 7 through 9 4 Clean burner see Cleaning and Mainte nance page 18 or replace burner orifice 1 Turn heater off when using furniture polish wax carpet cleaners or si...

Page 21: ...th most heaters If noise is excessive contact qualified ser vice person 1 Open window and ventilate room Stop using odor causing products while heater is running 2 Locate and correct all leaks see Check ing Gas Connections page 13 1 Open window and or door for ventilation 2 Contact local natural gas company 3 Clean ODS pilot see Cleaning and Maintenance page 18 1 Locate and correct all leaks see C...

Page 22: ...FLAME MAX GOLDEN OAK LOG MODELS VYD18PRA VYD24PRA VYD30PRA AND VYD36PR 4 13 13 14 22 13 8 18 7 6 9 1 12 5 23 16 15 17 3 11 2 10 10 19 24 19 20 21 O F F P I L O T O N H I L O O F F P I L O T O N H I L O Note The Golden Oak Log 104254 01 for the VYD36PR model differs slightly from the log shown ...

Page 23: ...3345 01 Lower Bracket 1 13 M11084 38 M11084 38 M11084 38 M11084 38 Screw 8 x 38 7 14 104384 01 102775 06CK 102775 08CK 102775 08CK Painted Base Assy 1 15 098271 07 098271 07 098271 07 098271 07 Ignitor Cable 1 16 102445 01 102445 01 102445 01 102445 01 Piezo Ignitor 1 17 103587 02 103587 02 103587 02 103587 02 Plate Switch 1 18 104099 01 104099 01 104099 01 104099 01 Heat Shield 1 19 098304 01 098...

Page 24: ...olden Oak Golden Oak 18 Remote 24 30 and 36 Ready Remote Ready Btu Variable 16 000 30 000 20 000 39 000 Type Gas Propane Only Propane Only Ignition Piezo Piezo Pressure Manifold 8 0 W C 8 0 W C Inlet Gas Pressure in of water Maximum 14 14 Minimum 11 11 Shipping Weight 28 lbs 30 lbs 24 32 lbs 30 34 lbs 36 For input adjustment SERVICE HINTS When Gas Pressure Is Too Low pilot will not stay lit burner...

Page 25: ...g heater to be operated in a manually or thermostati cally controlled mode You can turn the gas log heater on and off without ever leaving the comfort of your easy chair RECEIVER AND HAND HELD REMOTE CONTROL KIT GHRC Forallmodels Allowsthegaslogheaterto be turned on and off by using a hand held remote control WALL MOUNT THERMOSTAT SWITCH GWMT1 Not Shown For all models The desired comfort setting c...

Page 26: ... warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO ...

Reviews: